N5H8T36*K*AAA*
2-STAGE 18 SEER HP · source records, page 13
257 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 257 / 257 |
| EER2 · BTU/Wh | 11.7–13 | 257 / 257 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 257 / 257 |
| Cooling capacity · BTU/h | 33,800–38,000 | 257 / 257 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,200–39,000 | 257 / 257 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 23,000–24,200 | 257 / 257 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,500–19,600 | 257 / 257 |
| COP at 5°F / −15°C | 1.78–2.48 | 257 / 257 |
| Equipment / loop type | HP - Split System | 257 / 257 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 257 / 257 |
| Compressor staging | Two-stage | 257 / 257 |
| Connected capability | No | 257 / 257 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
ESH5X42M12A*+ furnace: *80VTL0902120B*AHRI reference: 215641319 | 15.20 | 7.80 | 19100 | 2.26 | EPA 3956756 → |
ESH5X48M12A*+ furnace: *96CTN1002122B*AHRI reference: 215642826 | 15.20 | 8.10 | 19100 | 2.26 | EPA 3956777 → |
ESH5X48M12A*+ furnace: *96VTN1002120B*AHRI reference: 215642928 | 15.20 | 8.10 | 19100 | 2.26 | EPA 3956799 → |
ESH5X48M12A*+ furnace: *96VTN1002122B*AHRI reference: 215642951 | 15.20 | 8.10 | 19100 | 2.26 | EPA 3956827 → |
ESH5X48M12A*+ furnace: *96VTN1202422B*AHRI reference: 215642977 | 15.20 | 8.10 | 19300 | 2.24 | EPA 3956839 → |
ESH5X42M12A*+ furnace: *80VTL1102122B*AHRI reference: 215641343 | 15.20 | 7.80 | 19000 | 2.26 | EPA 3956849 → |
ESH5X42M12A*+ furnace: *95CSU1002122B*AHRI reference: 215641432 | 15.20 | 7.80 | 19000 | 2.26 | EPA 3956884 → |
ESH5X42M12A*+ furnace: *96VTN1002122B*AHRI reference: 215641904 | 15.20 | 7.80 | 18800 | 2.26 | EPA 3956888 → |
ESH5X42M12A*+ furnace: OLV154F20AAHRI reference: 215641952 | 15.20 | 8.10 | 19100 | 2.26 | EPA 3956902 → |
ESH5X48M12A*+ furnace: OLV154F20AAHRI reference: 215642997 | 15.20 | 8.10 | 19100 | 2.26 | EPA 3956919 → |
ESH5X48M12A*+ furnace: *80VSL0902120B*AHRI reference: 215642089 | 15.20 | 8.10 | 19200 | 2.24 | EPA 3957103 → |
ESH5X48M12A*+ furnace: *80VSL1102122B*AHRI reference: 215642109 | 15.20 | 8.10 | 19100 | 2.26 | EPA 3957118 → |
ESH5X48M12A*+ furnace: *80MSU0601716A*AHRI reference: 215642183 | 15.20 | 8.10 | 19000 | 2.26 | EPA 3957130 → |
ESH5X48M12A*+ furnace: *80MSU0802120A*AHRI reference: 215642211 | 15.20 | 8.10 | 19000 | 2.26 | EPA 3957160 → |
ESH5X48M12A*+ furnace: *80MSU1002120A*AHRI reference: 215642239 | 15.20 | 7.80 | 19000 | 2.26 | EPA 3957174 → |
FTMA5B36L0C*AHRI reference: 215560701 | 15.20 | 8.10 | 18800 | 2.20 | EPA 3982793 → |
EA*5X37M17A*+ furnace: *97VTN0601716A*AHRI reference: 215721335 | 15.20 | 8.10 | 19000 | 2.24 | EPA 4705718 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →