Tempstar / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 4

514 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5514 / 514
EER2 · BTU/Wh11.5–14514 / 514
HSPF2 · BTU/Wh7.8–8.5514 / 514
Cooling capacity · BTU/h22,200–25,000514 / 514
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400514 / 514
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000514 / 514
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500514 / 514
COP at 5°F / −15°C1.9–2.24514 / 514
Equipment / loop typeHP - Split System514 / 514
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)514 / 514
Compressor stagingTwo-stage514 / 514
Connected capabilityNo514 / 514

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+ furnace: *96CTN0802120B*AHRI reference: 21564859217.508.00112002.10EPA 3719654 →
EVM5X31M17A*+ furnace: *80VSL0451412B*AHRI reference: 21561383517.507.80109001.98EPA 3946002 →
EA*5X25M17A*+ furnace: *80VSL0451412B*AHRI reference: 21564439717.508.10110002.10EPA 3957795 →
EA*5X25M17A*+ furnace: *80VSL0901716B*AHRI reference: 21564445617.508.10111002.10EPA 3957819 →
EA*5X25M17A*+ furnace: *80MSU0601716A*AHRI reference: 21564450917.508.10110002.10EPA 3957864 →
EA*5X25M17A*+ furnace: *80CTL0701716B*AHRI reference: 21564457417.508.10111002.10EPA 3957911 →
EA*5X25M17A*+ furnace: *80CTL0901716B*AHRI reference: 21564459417.508.10111002.10EPA 3957926 →
EA*5X25M17A*+ furnace: *80VTL0451412B*AHRI reference: 21564461817.508.10110002.10EPA 3957937 →
EA*5X25M17A*+ furnace: *80VTL0701716B*AHRI reference: 21564466217.508.10111002.10EPA 3957968 →
EA*5X25M17A*+ furnace: *95CSU0601716B*AHRI reference: 21564469917.508.10111002.10EPA 3957992 →
EA*5X25M17A*+ furnace: *97CMN0601714B*AHRI reference: 21564472017.508.10111002.08EPA 3958004 →
EA*5X25M17A*+ furnace: *97CMN0801714B*AHRI reference: 21564474017.508.10111002.08EPA 3958020 →
EA*5X25M17A*+ furnace: *96VTN0801716B*AHRI reference: 21564509217.508.10111002.08EPA 3958046 →
EA*5X25M17A*+ furnace: *96VSN0601716B*AHRI reference: 21564481817.508.10112002.08EPA 3958078 →
EA*5X25M17A*+ furnace: *96VSN0801716B*AHRI reference: 21564483717.508.10111002.08EPA 3958098 →
EA*5X25M17A*+ furnace: *95MSU0601716A*AHRI reference: 21564489017.508.10111002.10EPA 3958127 →
EA*5X25M17A*+ furnace: *96CTN0601714B*AHRI reference: 21564493717.508.10111002.08EPA 3958161 →
EA*5X25M17A*+ furnace: *96CTN0801714B*AHRI reference: 21564495817.508.10111002.10EPA 3958181 →
EA*5X25M17A*+ furnace: *96VTN0601716B*AHRI reference: 21564506317.508.10112002.08EPA 3958248 →
EA*5X25M17A*+ furnace: OMV098J12*AHRI reference: 21564513717.508.10111002.10EPA 3958278 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.