Tempstar / AIR-SOURCE HEAT PUMP

D5CURAH24AAK+KSAIC0701230

Crossover Heat Pump · Crossover heat pump · source records, page 4

126 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity23,200–25,200BTU/h

Each efficiency range summarizes published EPA records for D5CURAH24AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 126 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16126 / 126
EER2 · BTU/Wh9.5–10126 / 126
HSPF2 · BTU/Wh8.5–9.5126 / 126
Cooling capacity · BTU/h23,200–25,200126 / 126
Heating capacity at 47°F / 8.3°C · BTU/h24,000–26,000126 / 126
Heating capacity at 17°F / −8.3°C · BTU/h18,300–19,500126 / 126
Heating capacity at 5°F / −15°C · BTU/h19,000–20,000126 / 126
COP at 5°F / −15°C1.88–2.14126 / 126
Equipment / loop typeHP - Split System126 / 126
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)126 / 126
Compressor stagingContinuously variable126 / 126
Connected capabilityNo126 / 126

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 21849778415.508.50190001.96EPA 4638165
EA*5X37M21A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 21849777015.508.50190001.96EPA 4638176
EA*5X36M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 21849776315.508.50194001.90EPA 4638183
EA*5X37M21A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 21849774215.508.50191001.96EPA 4638204
EA*5X37M21A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 21849766315.508.50191001.96EPA 4638227
EA*5X37M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 21849765615.508.50193001.94EPA 4638234
FM(C,U)5S36**AL*Cold climate designationAHRI reference: 21860952815.509.50200002.00EPA 4652453
FM(C,U)5S30**AL*Cold climate designationAHRI reference: 21860951915.509.50200002.00EPA 4652462
ESH5X36M12A*+ furnace: *92MSN0802120A*Cold climate designationAHRI reference: 21849725915.208.50193001.92EPA 4636975
EA*5X37M17A*+ furnace: *92MSN0601412A*Cold climate designationAHRI reference: 21849719615.208.50192001.96EPA 4636983
EA*5X36M17A*+ furnace: *92MSN0601412A*Cold climate designationAHRI reference: 21849718915.208.50194001.92EPA 4636990
ESH5X30M12A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 21849715415.208.50195001.92EPA 4636997
ESH5X30M12A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 21849714015.208.50195001.90EPA 4637011
EA*5X37M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 21849713315.208.50191001.96EPA 4637018
ESH5X30M12A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 21849711915.208.50195001.92EPA 4637032
EA*5X36M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 21849710515.208.50194001.90EPA 4637039
EA*5X30M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 21849709815.208.50194001.90EPA 4637046
ESH5X36M12A*+ furnace: *80MS(N,L)1102120A*Cold climate designationAHRI reference: 21849708415.208.50192001.94EPA 4637053
EA*5X30M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 21849704915.208.50194001.90EPA 4637074
ESH5X36M12A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 21849704215.208.50192001.94EPA 4637081

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →