D5CUHAH36AAK+KSAIC0701230
Crossover Heat Pump · source records, page 14
316 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH36AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 316 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 316 / 316 |
| EER2 · BTU/Wh | 9.4–10.5 | 316 / 316 |
| HSPF2 · BTU/Wh | 8.1–9 | 316 / 316 |
| Cooling capacity · BTU/h | 34,200–38,000 | 316 / 316 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,400–40,000 | 316 / 316 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–26,200 | 316 / 316 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,800–31,600 | 316 / 316 |
| COP at 5°F / −15°C | 1.75–1.9 | 316 / 316 |
| Equipment / loop type | HP - Split System | 316 / 316 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 316 / 316 |
| Compressor staging | Continuously variable | 316 / 316 |
| Connected capability | No | 316 / 316 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X42M21A*+ furnace: *80MS(N,L)0902116A*Cold climate designationAHRI reference: 218495384 | 15.50 | 8.50 | 30800 | 1.78 | EPA 4637757 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0902116A*Cold climate designationAHRI reference: 218495377 | 15.50 | 8.50 | 30200 | 1.84 | EPA 4637764 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0901714A*Cold climate designationAHRI reference: 218495349 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4637771 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0901714A*Cold climate designationAHRI reference: 218495342 | 15.50 | 8.50 | 30200 | 1.84 | EPA 4637778 → |
EA*5X42M21A*+ furnace: *80MS(N,L)0901714A*Cold climate designationAHRI reference: 218495335 | 15.50 | 8.50 | 30800 | 1.80 | EPA 4637785 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0901714A*Cold climate designationAHRI reference: 218495328 | 15.50 | 8.50 | 30200 | 1.82 | EPA 4637792 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0702116A*Cold climate designationAHRI reference: 218495286 | 15.50 | 8.50 | 30200 | 1.84 | EPA 4637813 → |
EA*5X42M21A*+ furnace: *80MS(N,L)0702116A*Cold climate designationAHRI reference: 218495279 | 15.50 | 8.50 | 30800 | 1.78 | EPA 4637820 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0702116A*Cold climate designationAHRI reference: 218495272 | 15.50 | 8.50 | 30200 | 1.84 | EPA 4637827 → |
EA*5X48M21A*+ furnace: *96MSN1002120A*Cold climate designationAHRI reference: 218516546 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4638263 → |
EA*5X48M21A*+ furnace: *92MSN0601714A*Cold climate designationAHRI reference: 218516525 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4638284 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0902116A*Cold climate designationAHRI reference: 218516518 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4638291 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0702116A*Cold climate designationAHRI reference: 218516511 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4638298 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0701716A*Cold climate designationAHRI reference: 218516504 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4638305 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 218516497 | 15.50 | 8.10 | 30000 | 1.75 | EPA 4638312 → |
ESH5X36M12A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 218492877 | 15.20 | 8.10 | 30800 | 1.75 | EPA 4635003 → |
ESH5X36M12A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 218492835 | 15.20 | 8.10 | 30800 | 1.75 | EPA 4635024 → |
ESH5X36M12A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 218492793 | 15.20 | 8.10 | 30800 | 1.75 | EPA 4635045 → |
ESH5X36M12A*+ furnace: *96VSN1202422B*Cold climate designationAHRI reference: 218492765 | 15.20 | 8.10 | 30800 | 1.75 | EPA 4635052 → |
ESH5X36M12A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 218492674 | 15.20 | 8.10 | 30600 | 1.75 | EPA 4635101 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →