D5CUHAH30AAK+KSAIC0701230
Crossover Heat Pump · source records, page 5
336 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH30AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 336 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 336 / 336 |
| EER2 · BTU/Wh | 9.5–10.5 | 336 / 336 |
| HSPF2 · BTU/Wh | 8.1–9 | 336 / 336 |
| Cooling capacity · BTU/h | 28,600–31,200 | 336 / 336 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 35,800–37,400 | 336 / 336 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,800–21,600 | 336 / 336 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–33,400 | 336 / 336 |
| COP at 5°F / −15°C | 1.75–2 | 336 / 336 |
| Equipment / loop type | HP - Split System | 336 / 336 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 336 / 336 |
| Compressor staging | Continuously variable | 336 / 336 |
| Connected capability | No | 336 / 336 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X43M21A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 218490063 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4633542 → |
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*Cold climate designationAHRI reference: 218490056 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4633549 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0902120A*Cold climate designationAHRI reference: 218490049 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4633556 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0902116A*Cold climate designationAHRI reference: 218490042 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4633563 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0901714A*Cold climate designationAHRI reference: 218490035 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4633570 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0702116A*Cold climate designationAHRI reference: 218490028 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4633577 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 218490014 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4633591 → |
EA*5X37M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 218491205 | 16.00 | 9.00 | 32400 | 1.94 | EPA 4633703 → |
EA*5X37M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 218491198 | 16.00 | 9.00 | 32400 | 1.94 | EPA 4633710 → |
EA*5X37M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 218491191 | 16.00 | 9.00 | 32400 | 1.92 | EPA 4633717 → |
EA*5X37M21A*+ furnace: OMV112K14ACold climate designationAHRI reference: 218491142 | 16.00 | 9.00 | 32200 | 2.00 | EPA 4633759 → |
EA*5X37M21A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218491093 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4633794 → |
EA*5X37M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218491086 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4633801 → |
EA*5X37M21A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218491058 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4633829 → |
EA*5X37M21A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218491051 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4633836 → |
EA*5X37M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 218491023 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4633864 → |
EA*5X37M21A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 218491016 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4633871 → |
EA*5X37M21A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 218491009 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4633878 → |
EA*5X37M21A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 218490988 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4633899 → |
EA*5X37M21A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218490981 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4633906 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.