D5CUHAH30AAK+KSAIC0701230
Crossover Heat Pump · source records, page 13
336 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH30AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 336 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 336 / 336 |
| EER2 · BTU/Wh | 9.5–10.5 | 336 / 336 |
| HSPF2 · BTU/Wh | 8.1–9 | 336 / 336 |
| Cooling capacity · BTU/h | 28,600–31,200 | 336 / 336 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 35,800–37,400 | 336 / 336 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,800–21,600 | 336 / 336 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–33,400 | 336 / 336 |
| COP at 5°F / −15°C | 1.75–2 | 336 / 336 |
| Equipment / loop type | HP - Split System | 336 / 336 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 336 / 336 |
| Compressor staging | Continuously variable | 336 / 336 |
| Connected capability | No | 336 / 336 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X43M21A*+ furnace: *96VSN0401712B*Cold climate designationAHRI reference: 218490212 | 15.50 | 9.00 | 32400 | 1.96 | EPA 4634631 → |
EA*5X43M21A*+ furnace: *96MSN1002122A*Cold climate designationAHRI reference: 218490205 | 15.50 | 9.00 | 32200 | 1.98 | EPA 4634638 → |
EA*5X43M21A*+ furnace: *96MSN0802120A*Cold climate designationAHRI reference: 218490191 | 15.50 | 9.00 | 32200 | 1.96 | EPA 4634652 → |
EA*5X43M21A*+ furnace: *96MSN0801716A*Cold climate designationAHRI reference: 218490183 | 15.50 | 9.00 | 32200 | 1.98 | EPA 4634660 → |
EA*5X30M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 218491936 | 15.50 | 8.50 | 33400 | 1.78 | EPA 4635579 → |
EA*5X36M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218491655 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635635 → |
EA*5X36M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218491648 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635642 → |
EA*5X36M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218491641 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635649 → |
EA*5X36M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218491634 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635656 → |
EA*5X36M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 218491599 | 15.50 | 8.50 | 33400 | 1.76 | EPA 4635677 → |
EA*5X36M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 218491592 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635684 → |
EA*5X36M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218491585 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635691 → |
EA*5X36M17A*+ furnace: *92MSN0801716A*Cold climate designationAHRI reference: 218491528 | 15.50 | 8.50 | 33200 | 1.76 | EPA 4635705 → |
EA*5X36M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 218491500 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635733 → |
EA*5X36M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 218491458 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635775 → |
EA*5X36M17A*+ furnace: *80MS(N,L)0901714A*Cold climate designationAHRI reference: 218491451 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635782 → |
EA*5X36M17A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 218491437 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635796 → |
EA*5X36M17A*+ furnace: *80MS(N,L)0701412A*Cold climate designationAHRI reference: 218491430 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635803 → |
EA*5X37M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 218491409 | 15.50 | 9.00 | 32600 | 1.98 | EPA 4635817 → |
EA*5X37M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 218491360 | 15.50 | 9.00 | 32600 | 1.94 | EPA 4635852 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →