D5CUHAH24AAK+KSAIC0701230
Crossover Heat Pump · source records, page 14
499 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH24AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 499 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 499 / 499 |
| EER2 · BTU/Wh | 10–11 | 499 / 499 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 499 / 499 |
| Cooling capacity · BTU/h | 22,600–25,000 | 499 / 499 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–25,800 | 499 / 499 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–18,700 | 499 / 499 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,600 | 499 / 499 |
| COP at 5°F / −15°C | 1.85–2.06 | 499 / 499 |
| Equipment / loop type | HP - Split System | 499 / 499 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 499 / 499 |
| Compressor staging | Continuously variable | 499 / 499 |
| Connected capability | No | 499 / 499 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
ESH5X30M12A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 218487886 | 16.00 | 8.50 | 19500 | 1.90 | EPA 4630351 → |
ESH5X30M12A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 218487879 | 16.00 | 8.50 | 19600 | 1.90 | EPA 4630358 → |
ESH5X30M12A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 218487830 | 16.00 | 8.50 | 19600 | 1.90 | EPA 4630407 → |
ESH5X30M12A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 218487823 | 16.00 | 8.50 | 19500 | 1.90 | EPA 4630414 → |
ESH5X30M12A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 218487809 | 16.00 | 8.50 | 19500 | 1.90 | EPA 4630428 → |
ESH5X24M12A*+ furnace: *97VTN1202422A*Cold climate designationAHRI reference: 218487781 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4630435 → |
ESH5X24M12A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 218487767 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4630449 → |
ESH5X24M12A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 218487760 | 16.00 | 8.50 | 19700 | 1.92 | EPA 4630456 → |
ESH5X24M12A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218487746 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4630470 → |
ESH5X24M12A*+ furnace: *96VTN1202422B*Cold climate designationAHRI reference: 218487739 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4630477 → |
ESH5X24M12A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 218487725 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4630491 → |
ESH5X24M12A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 218487718 | 16.00 | 8.50 | 19700 | 1.92 | EPA 4630498 → |
ESH5X24M12A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218487704 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4630512 → |
ESH5X24M12A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 218487697 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4630519 → |
ESH5X24M12A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 218487676 | 16.00 | 8.50 | 19800 | 1.88 | EPA 4630533 → |
ESH5X24M12A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 218487655 | 16.00 | 8.50 | 19800 | 1.88 | EPA 4630554 → |
ESH5X24M12A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218487613 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4630596 → |
ESH5X24M12A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 218487571 | 16.00 | 8.50 | 19800 | 1.88 | EPA 4630638 → |
ESH5X24M12A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 218487564 | 16.00 | 8.50 | 19700 | 1.90 | EPA 4630645 → |
ESH5X24M12A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 218487557 | 16.00 | 8.50 | 20000 | 1.88 | EPA 4630652 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.