B5H6S36*K*AAA*
MAINLINE 16 SEER2 HP
26 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H6S36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 26 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–15.5 | 26 / 26 |
| EER2 · BTU/Wh | 11.7–13 | 26 / 26 |
| HSPF2 · BTU/Wh | 7.8 | 26 / 26 |
| Cooling capacity · BTU/h | 33,800–36,800 | 26 / 26 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,200–36,200 | 26 / 26 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,000–22,800 | 26 / 26 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,700–18,100 | 26 / 26 |
| COP at 5°F / −15°C | 2–2.24 | 26 / 26 |
| Equipment / loop type | HP - Split System | 26 / 26 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 26 / 26 |
| Compressor staging | Single stage | 26 / 26 |
| Connected capability | No | 26 / 26 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FEVA0048**+NAVA54801CKAHRI reference: 218209615 | 15.50 | 7.80 | 17400 | 2.22 | EPA 4584191 → |
F5MA5*48L*C*AHRI reference: 218209614 | 15.50 | 7.80 | 17500 | 2.24 | EPA 4584192 → |
FMA5X36**AL*AHRI reference: 218209498 | 15.50 | 7.80 | 17000 | 2.00 | EPA 4584196 → |
FEVB0048**+NAVA54801CKAHRI reference: 218209496 | 15.50 | 7.80 | 17400 | 2.22 | EPA 4584197 → |
FHMA5*48L*C*AHRI reference: 218209435 | 15.50 | 7.80 | 17500 | 2.24 | EPA 4584198 → |
FTMA5B48L0C*AHRI reference: 218209434 | 15.50 | 7.80 | 16700 | 2.18 | EPA 4584199 → |
F5MA5*42L*C*AHRI reference: 218209613 | 15.20 | 7.80 | 17000 | 2.14 | EPA 4584193 → |
FM(C,U)5Z36**AL*AHRI reference: 218209611 | 15.20 | 7.80 | 17200 | 2.08 | EPA 4584194 → |
EA*5X48M21A*+WALLCON+ furnace: *96CTN0802120B*AHRI reference: 218209535 | 15.20 | 7.80 | 17500 | 2.18 | EPA 4584195 → |
FHMA5*42L*C*AHRI reference: 218209433 | 15.20 | 7.80 | 17000 | 2.14 | EPA 4584200 → |
EVD5X42M24A*+ furnace: *80MSU1002120A*AHRI reference: 218209177 | 15.20 | 7.80 | 18100 | 2.14 | EPA 4584201 → |
EA*5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 218209122 | 15.20 | 7.80 | 17500 | 2.20 | EPA 4584202 → |
EA*5X48M21A*+ furnace: *96CTN0802120B*AHRI reference: 218209119 | 15.20 | 7.80 | 17500 | 2.18 | EPA 4584203 → |
EA*5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 218209118 | 15.20 | 7.80 | 17600 | 2.18 | EPA 4584204 → |
EA*5X48M21A*+ furnace: *92MSN1002120A*AHRI reference: 218209112 | 15.20 | 7.80 | 17600 | 2.18 | EPA 4584205 → |
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 218209107 | 15.20 | 7.80 | 17500 | 2.18 | EPA 4584206 → |
EA*5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 218209106 | 15.20 | 7.80 | 17500 | 2.18 | EPA 4584207 → |
EA*5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 218209103 | 15.20 | 7.80 | 17300 | 2.20 | EPA 4584208 → |
EA*5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 218209102 | 15.20 | 7.80 | 17600 | 2.18 | EPA 4584209 → |
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 218209099 | 15.20 | 7.80 | 17500 | 2.18 | EPA 4584210 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →