Tempstar / AIR-SOURCE HEAT PUMP

B5H6S36*K*AAA*

MAINLINE 16 SEER2 HP

26 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity33,800–36,800BTU/h

Each efficiency range summarizes published EPA records for B5H6S36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 26 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.526 / 26
EER2 · BTU/Wh11.7–1326 / 26
HSPF2 · BTU/Wh7.826 / 26
Cooling capacity · BTU/h33,800–36,80026 / 26
Heating capacity at 47°F / 8.3°C · BTU/h33,200–36,20026 / 26
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,80026 / 26
Heating capacity at 5°F / −15°C · BTU/h16,700–18,10026 / 26
COP at 5°F / −15°C2–2.2426 / 26
Equipment / loop typeHP - Split System26 / 26
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)26 / 26
Compressor stagingSingle stage26 / 26
Connected capabilityNo26 / 26

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FEVA0048**+NAVA54801CKAHRI reference: 21820961515.507.80174002.22EPA 4584191
F5MA5*48L*C*AHRI reference: 21820961415.507.80175002.24EPA 4584192
FMA5X36**AL*AHRI reference: 21820949815.507.80170002.00EPA 4584196
FEVB0048**+NAVA54801CKAHRI reference: 21820949615.507.80174002.22EPA 4584197
FHMA5*48L*C*AHRI reference: 21820943515.507.80175002.24EPA 4584198
FTMA5B48L0C*AHRI reference: 21820943415.507.80167002.18EPA 4584199
F5MA5*42L*C*AHRI reference: 21820961315.207.80170002.14EPA 4584193
FM(C,U)5Z36**AL*AHRI reference: 21820961115.207.80172002.08EPA 4584194
EA*5X48M21A*+WALLCON+ furnace: *96CTN0802120B*AHRI reference: 21820953515.207.80175002.18EPA 4584195
FHMA5*42L*C*AHRI reference: 21820943315.207.80170002.14EPA 4584200
EVD5X42M24A*+ furnace: *80MSU1002120A*AHRI reference: 21820917715.207.80181002.14EPA 4584201
EA*5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 21820912215.207.80175002.20EPA 4584202
EA*5X48M21A*+ furnace: *96CTN0802120B*AHRI reference: 21820911915.207.80175002.18EPA 4584203
EA*5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 21820911815.207.80176002.18EPA 4584204
EA*5X48M21A*+ furnace: *92MSN1002120A*AHRI reference: 21820911215.207.80176002.18EPA 4584205
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21820910715.207.80175002.18EPA 4584206
EA*5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 21820910615.207.80175002.18EPA 4584207
EA*5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 21820910315.207.80173002.20EPA 4584208
EA*5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 21820910215.207.80176002.18EPA 4584209
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 21820909915.207.80175002.18EPA 4584210

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →