Tempstar / AIR-SOURCE HEAT PUMP

B5H6S31*K*AAA*

MAINLINE 16 SEER2 HP · source records, page 2

38 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity27,400–29,400BTU/h

Each efficiency range summarizes published EPA records for B5H6S31*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 38 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1638 / 38
EER2 · BTU/Wh11.7–1338 / 38
HSPF2 · BTU/Wh7.8–838 / 38
Cooling capacity · BTU/h27,400–29,40038 / 38
Heating capacity at 47°F / 8.3°C · BTU/h29,200–30,60038 / 38
Heating capacity at 17°F / −8.3°C · BTU/h17,300–18,20038 / 38
Heating capacity at 5°F / −15°C · BTU/h13,100–14,00038 / 38
COP at 5°F / −15°C2–2.0638 / 38
Equipment / loop typeHP - Split System38 / 38
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)38 / 38
Compressor stagingSingle stage38 / 38
Connected capabilityNo38 / 38

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 21820442115.508.00140002.04EPA 4584009 →
EA*5X43M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21820441815.508.00140002.06EPA 4584010 →
EA*5X43M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21820440215.508.00139002.04EPA 4584011 →
EA*5X43M21A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 21820439815.508.00139002.06EPA 4584012 →
EA*5X37M21A*+ furnace: *97VTN1002122A*AHRI reference: 21820437915.508.00140002.06EPA 4584016 →
EA*5X37M21A*+ furnace: *96VTN1002122B*AHRI reference: 21820437415.508.00140002.06EPA 4584017 →
EA*5X37M21A*+ furnace: *95MSU1002122A*AHRI reference: 21820435315.508.00140002.06EPA 4584018 →
EA*5X37M21A*+ furnace: *92MSN1002122A*AHRI reference: 21820432415.508.00140002.06EPA 4584019 →
EA*5X37M21A*+ furnace: *92MSN1002120A*AHRI reference: 21820432115.508.00140002.06EPA 4584020 →
EA*5X37M21A*+ furnace: *92MSN0802120A*AHRI reference: 21820432015.508.00140002.06EPA 4584021 →
EA*5X37M21A*+ furnace: *80MSU0802120A*AHRI reference: 21820427515.508.00140002.04EPA 4584031 →
EA*5X37M21A*+ furnace: *80MSU0601716A*AHRI reference: 21820427415.508.00140002.06EPA 4584032 →
EA*5X37M21A*+ furnace: *80VSL1102122B*AHRI reference: 21820427015.508.00140002.06EPA 4584033 →
EA*5X37M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 21820426215.508.00140002.06EPA 4584034 →
EA*5X37M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21820425915.508.00140002.06EPA 4584035 →
EA*5X37M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21820424615.508.00140002.06EPA 4584036 →
EA*5X37M21A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 21820424215.508.00139002.06EPA 4584037 →
FMA5L30**AL*AHRI reference: 21820532615.208.00138002.00EPA 4583946 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →