B5H3V36*K*AAA*
SmartSense 23 VS HP · source records, page 6
514 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 514 / 514 |
| EER2 · BTU/Wh | 10–12.5 | 514 / 514 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 514 / 514 |
| Cooling capacity · BTU/h | 32,000–36,000 | 514 / 514 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 514 / 514 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 514 / 514 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 514 / 514 |
| COP at 5°F / −15°C | 1.92–2.1 | 514 / 514 |
| Equipment / loop type | HP - Split System | 514 / 514 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 514 / 514 |
| Compressor staging | Continuously variable | 514 / 514 |
| Connected capability | No | 514 / 514 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X61M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218416464 | 22.00 | 8.50 | 28200 | 2.08 | EPA 4608077 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218416448 | 22.00 | 8.50 | 28200 | 2.06 | EPA 4608093 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218416440 | 22.00 | 8.50 | 28400 | 2.06 | EPA 4608101 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218416432 | 22.00 | 8.50 | 28400 | 2.06 | EPA 4608109 → |
EVM5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218416408 | 22.00 | 8.50 | 28200 | 2.06 | EPA 4608133 → |
EVM5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218416400 | 22.00 | 8.50 | 28200 | 2.06 | EPA 4608141 → |
EVM5X61M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218416392 | 22.00 | 8.50 | 28200 | 2.06 | EPA 4608149 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218416384 | 22.00 | 8.50 | 28200 | 2.06 | EPA 4608157 → |
FCMA5B48L0C*+WALLCONCold climate designationAHRI reference: 218405879 | 21.50 | 9.50 | 25800 | 2.06 | EPA 4601651 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218411767 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4603727 → |
EVM5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218411743 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4603751 → |
EVM5X60M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218411719 | 21.50 | 8.50 | 28400 | 2.06 | EPA 4603775 → |
EVM5X60M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218411695 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4603799 → |
EVM5X60M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218411663 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4603831 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218411647 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4603847 → |
EVM5X60M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218411615 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4603879 → |
EVM5X60M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 218411607 | 21.50 | 8.50 | 28800 | 2.04 | EPA 4603887 → |
EVM5X60M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218411591 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4603903 → |
EVM5X60M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218411583 | 21.50 | 8.50 | 29000 | 2.04 | EPA 4603911 → |
EVM5X60M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218411559 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4603935 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →