B5H3V36*K*AAA*
SmartSense 23 VS HP · source records, page 15
514 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 514 / 514 |
| EER2 · BTU/Wh | 10–12.5 | 514 / 514 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 514 / 514 |
| Cooling capacity · BTU/h | 32,000–36,000 | 514 / 514 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 514 / 514 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 514 / 514 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 514 / 514 |
| COP at 5°F / −15°C | 1.92–2.1 | 514 / 514 |
| Equipment / loop type | HP - Split System | 514 / 514 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 514 / 514 |
| Compressor staging | Continuously variable | 514 / 514 |
| Connected capability | No | 514 / 514 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218409935 | 20.50 | 9.00 | 26000 | 1.98 | EPA 4605559 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218409911 | 20.50 | 9.00 | 26000 | 1.96 | EPA 4605583 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218409903 | 20.50 | 9.00 | 26000 | 1.96 | EPA 4605591 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218409895 | 20.50 | 9.00 | 26200 | 1.96 | EPA 4605599 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218409887 | 20.50 | 9.00 | 26200 | 1.96 | EPA 4605607 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218409863 | 20.50 | 9.00 | 26000 | 1.96 | EPA 4605631 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218409855 | 20.50 | 9.00 | 26000 | 1.96 | EPA 4605639 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 218409847 | 20.50 | 9.00 | 26000 | 1.96 | EPA 4605647 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218409839 | 20.50 | 9.00 | 25800 | 1.96 | EPA 4605655 → |
FCMA5B36L0C*+WALLCONCold climate designationAHRI reference: 218413175 | 20.50 | 9.50 | 25800 | 2.00 | EPA 4606319 → |
EVD5X48M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218412511 | 20.50 | 8.50 | 27600 | 2.08 | EPA 4606983 → |
EVD5X48M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 218412503 | 20.50 | 8.50 | 27600 | 2.08 | EPA 4606991 → |
EVD5X42M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218412359 | 20.50 | 8.50 | 28200 | 2.06 | EPA 4607135 → |
EVD5X42M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218412351 | 20.50 | 8.50 | 28600 | 2.06 | EPA 4607143 → |
EVD5X42M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218412327 | 20.50 | 8.50 | 28200 | 2.06 | EPA 4607167 → |
EVD5X42M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 218412319 | 20.50 | 8.50 | 28400 | 2.06 | EPA 4607175 → |
EVD5X42M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218412311 | 20.50 | 8.10 | 27000 | 2.00 | EPA 4607183 → |
EVD5X42M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218412295 | 20.50 | 8.50 | 28200 | 2.06 | EPA 4607199 → |
EVD5X42M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218412287 | 20.50 | 8.10 | 28600 | 2.00 | EPA 4607207 → |
EVD5X42M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 218412279 | 20.50 | 8.50 | 28600 | 2.06 | EPA 4607215 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →