B5H0V48*K*AAA*
SmartSense 20 VS HP · source records, page 9
327 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 327 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 327 / 327 |
| EER2 · BTU/Wh | 9–10.5 | 327 / 327 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 327 / 327 |
| Cooling capacity · BTU/h | 43,500–49,000 | 327 / 327 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 327 / 327 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 327 / 327 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 327 / 327 |
| COP at 5°F / −15°C | 1.92–2.2 | 327 / 327 |
| Equipment / loop type | HP - Split System | 327 / 327 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 327 / 327 |
| Compressor staging | Continuously variable | 327 / 327 |
| Connected capability | No | 327 / 327 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X60M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218165561 | 18.50 | 9.00 | 36600 | 2.00 | EPA 4596338 → |
EVM5X49M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218165557 | 18.50 | 9.00 | 37200 | 1.98 | EPA 4596342 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218165556 | 18.50 | 9.00 | 36600 | 2.00 | EPA 4596343 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218165554 | 18.50 | 9.00 | 36800 | 2.00 | EPA 4596345 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218165553 | 18.50 | 9.00 | 36600 | 2.00 | EPA 4596346 → |
EVM5X48M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218165551 | 18.50 | 9.00 | 36400 | 2.00 | EPA 4596348 → |
EVM5X48M21A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218165548 | 18.50 | 9.00 | 36200 | 2.00 | EPA 4596351 → |
EVD5X60M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218165463 | 18.50 | 9.00 | 37400 | 1.98 | EPA 4596366 → |
EVD5X60M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 218165462 | 18.50 | 9.00 | 37200 | 1.98 | EPA 4596367 → |
EVD5X60M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218165460 | 18.50 | 9.00 | 36800 | 2.00 | EPA 4596369 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218165454 | 18.50 | 9.00 | 37200 | 2.00 | EPA 4596398 → |
EVD5X49M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 218165447 | 18.50 | 9.00 | 37000 | 1.98 | EPA 4596405 → |
EVD5X48M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 218165441 | 18.50 | 9.00 | 36400 | 2.00 | EPA 4596411 → |
EVD5X48M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 218165440 | 18.50 | 9.00 | 36400 | 2.00 | EPA 4596412 → |
EVD5X48M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218165439 | 18.50 | 9.00 | 36400 | 2.00 | EPA 4596413 → |
EVD5X48M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218165438 | 18.50 | 9.00 | 36200 | 2.02 | EPA 4596414 → |
EVD5X48M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218165433 | 18.50 | 9.00 | 36600 | 2.02 | EPA 4596419 → |
EVD5X48M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218165432 | 18.50 | 9.00 | 36400 | 2.00 | EPA 4596420 → |
EVD5X48M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218165430 | 18.50 | 9.00 | 36400 | 2.00 | EPA 4596422 → |
EVD5X48M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218165428 | 18.50 | 9.00 | 36400 | 2.00 | EPA 4596424 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.