B5H0V48*K*AAA*
SmartSense 20 VS HP · source records, page 15
327 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 327 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 327 / 327 |
| EER2 · BTU/Wh | 9–10.5 | 327 / 327 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 327 / 327 |
| Cooling capacity · BTU/h | 43,500–49,000 | 327 / 327 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 327 / 327 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 327 / 327 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 327 / 327 |
| COP at 5°F / −15°C | 1.92–2.2 | 327 / 327 |
| Equipment / loop type | HP - Split System | 327 / 327 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 327 / 327 |
| Compressor staging | Continuously variable | 327 / 327 |
| Connected capability | No | 327 / 327 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X48M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218165288 | 17.50 | 9.00 | 34000 | 2.04 | EPA 4596553 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218165286 | 17.50 | 9.00 | 34000 | 2.04 | EPA 4596554 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218165285 | 17.50 | 9.00 | 34200 | 2.06 | EPA 4596555 → |
EA*5X48M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218165282 | 17.50 | 9.00 | 34200 | 2.06 | EPA 4596558 → |
EA*5X48M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218165278 | 17.50 | 9.00 | 34200 | 2.06 | EPA 4596562 → |
EA*5X48M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218165277 | 17.50 | 9.00 | 34200 | 2.06 | EPA 4596563 → |
EA*5X48M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218165276 | 17.50 | 9.00 | 34400 | 2.04 | EPA 4596564 → |
EA*5X48M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218165505 | 17.00 | 9.00 | 34600 | 2.04 | EPA 4579326 → |
EA*5X48M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218165504 | 17.00 | 9.00 | 34000 | 2.04 | EPA 4579327 → |
EA*5X48M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218165502 | 17.00 | 9.00 | 34200 | 2.04 | EPA 4579329 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218165540 | 17.00 | 8.50 | 33600 | 2.06 | EPA 4596359 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218165539 | 17.00 | 8.50 | 33800 | 2.08 | EPA 4596360 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 218165301 | 17.00 | 9.00 | 34600 | 2.06 | EPA 4596540 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218165284 | 17.00 | 9.00 | 34600 | 2.04 | EPA 4596556 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 218165283 | 17.00 | 9.00 | 34600 | 2.04 | EPA 4596557 → |
EA*5X48M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218165281 | 17.00 | 9.00 | 34600 | 2.04 | EPA 4596559 → |
EA*5X48M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 218165275 | 17.00 | 9.00 | 35000 | 2.02 | EPA 4596565 → |
ESH5X60M12A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 218165545 | 16.50 | 8.50 | 33800 | 2.08 | EPA 4596354 → |
ESH5X60M12A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218165544 | 16.50 | 8.50 | 33800 | 2.08 | EPA 4596355 → |
ESH5X60M12A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218165543 | 16.50 | 8.50 | 33800 | 2.06 | EPA 4596356 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.