THH18HAI2NAF2U23
TS1
7 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for THH18HAI2NAF2U23. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 7 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2 | 7 / 7 |
| EER2 · BTU/Wh | 9–9.8 | 7 / 7 |
| HSPF2 · BTU/Wh | 8.5 | 7 / 7 |
| Cooling capacity · BTU/h | 18,000–20,000 | 7 / 7 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 18,000–20,000 | 7 / 7 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,000–20,000 | 7 / 7 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,000–18,000 | 7 / 7 |
| COP at 5°F / −15°C | 1.85–1.9 | 7 / 7 |
| Equipment / loop type | HP - Split System | 7 / 7 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 7 / 7 |
| Compressor staging | Continuously variable | 7 / 7 |
| Connected capability | No | 7 / 7 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
4TXCB003DS3+ furnace: A951X040BU3SABCold climate designationAHRI reference: 212510663 | 15.20 | 8.50 | 18000 | 1.85 | EPA 2634823 → |
4TXCB003DS3+ furnace: A801X040BM2SCACold climate designationAHRI reference: 212510662 | 15.20 | 8.50 | 18000 | 1.85 | EPA 2634834 → |
4TXCB003DS3+ furnace: A952V040BU3SADCold climate designationAHRI reference: 212510664 | 15.20 | 8.50 | 18000 | 1.85 | EPA 2634853 → |
THH24IAI2NAF2H23Cold climate designationAHRI reference: 211603988 | 15.20 | 8.50 | 18000 | 1.90 | EPA 2634854 → |
A4AH5V24A1B3 + DFCold climate designationAHRI reference: 213880445 | 15.20 | 8.50 | 16000 | 1.90 | EPA 2862399 → |
4TXCB003DS3+ furnace: A801X040BM2SDCold climate designationAHRI reference: 215400238 | 15.20 | 8.50 | 18000 | 1.85 | EPA 3619754 → |
4TXCB003DS3+ furnace: A952V040BU3SBCold climate designationAHRI reference: 215400244 | 15.20 | 8.50 | 18000 | 1.85 | EPA 3619755 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.