SP17AY48AJVC
NONE · VANTIX · source records, page 5
111 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for SP17AY48AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 111 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 111 / 111 |
| EER2 · BTU/Wh | 9–11 | 111 / 111 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 111 / 111 |
| Cooling capacity · BTU/h | 44,000–45,500 | 111 / 111 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 44,000–45,500 | 111 / 111 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 39,000–40,000 | 111 / 111 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,200–37,600 | 111 / 111 |
| COP at 5°F / −15°C | 2–2.1 | 111 / 111 |
| Equipment / loop type | HP - Split System | 111 / 111 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 111 / 111 |
| Compressor staging | Continuously variable | 111 / 111 |
| Connected capability | Yes | 111 / 111 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY4824STANM+ furnace: S802V0755A21UHSCold climate designationAHRI reference: 218327467 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620994 → |
TCFY4821STANM+ furnace: S802V0755A21UHSCold climate designationAHRI reference: 218327466 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620995 → |
TCFY4824STANM+ furnace: S802V0755A21UHNCold climate designationAHRI reference: 218327465 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620996 → |
TCFY4821STANM+ furnace: S802V0755A21UHNCold climate designationAHRI reference: 218327464 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620997 → |
TCFY4824STANM+ furnace: S802V0755A21DZSCold climate designationAHRI reference: 218327463 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620998 → |
TCFY4821STANM+ furnace: S802V0755A21DZSCold climate designationAHRI reference: 218327462 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620999 → |
TCFY4824STANM+ furnace: S802V0755A21DZNCold climate designationAHRI reference: 218327461 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4621000 → |
TCFY4821STANM+ furnace: S802V0755A21DZNCold climate designationAHRI reference: 218327460 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4621001 → |
TCFY4821STANM+ furnace: S802V0754A17UHSCold climate designationAHRI reference: 218327459 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4621002 → |
TCFY4821STANM+ furnace: S802V0754A17UHNCold climate designationAHRI reference: 218327458 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4621003 → |
TCFY4821STANM+ furnace: S802V0754A17DZSCold climate designationAHRI reference: 218327457 | 16.00 | 9.50 | 37200 | 2.00 | EPA 4621004 → |
TCFY4821STANM+ furnace: S802V0754A17DZNCold climate designationAHRI reference: 218327456 | 16.00 | 9.50 | 37200 | 2.00 | EPA 4621005 → |
TCFY4824STANM+ furnace: S801V1505A24UHSCold climate designationAHRI reference: 218327453 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4621008 → |
TCFY4824STANM+ furnace: S801V1505A24UHNCold climate designationAHRI reference: 218327452 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4621009 → |
TCFY4824STANM+ furnace: S801V1255A24UHSCold climate designationAHRI reference: 218327451 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4621010 → |
TCFY4824STANM+ furnace: S801V1255A24UHNCold climate designationAHRI reference: 218327450 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4621011 → |
TCFY4824STANM+ furnace: S801V1255A24DZSCold climate designationAHRI reference: 218327449 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4621012 → |
SH2VY4821STACNCold climate designationAHRI reference: 218159982 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4621306 → |
TCFY4824STANM+ furnace: S972V1155A24UPSCold climate designationAHRI reference: 218719355 | 16.00 | 9.50 | 33200 | 2.10 | EPA 4691728 → |
TCFY4824STANM+ furnace: S972V1005A21UPSCold climate designationAHRI reference: 218719354 | 16.00 | 9.50 | 33400 | 2.10 | EPA 4691729 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →