SP17AY24AJVC
NONE · VANTIX
46 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for SP17AY24AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 46 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–17 | 46 / 46 |
| EER2 · BTU/Wh | 10–11.7 | 46 / 46 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 46 / 46 |
| Cooling capacity · BTU/h | 22,200–22,600 | 46 / 46 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–22,600 | 46 / 46 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,600–19,900 | 46 / 46 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,100–18,400 | 46 / 46 |
| COP at 5°F / −15°C | 2–2.2 | 46 / 46 |
| Equipment / loop type | HP - Split System | 46 / 46 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 46 / 46 |
| Compressor staging | Continuously variable | 46 / 46 |
| Connected capability | No · Yes | 46 / 46 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY2417STANM+ furnace: S951V0603A17M4SCold climate designationAHRI reference: 218327306 | 17.00 | 9.50 | 18300 | 2.10 | EPA 4584797 → |
TCFY2417STANM+ furnace: S951V0403A17M4SCold climate designationAHRI reference: 218327303 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584798 → |
TCFY2417STANM+ furnace: S921V0603A17M4SCold climate designationAHRI reference: 218327302 | 17.00 | 9.50 | 18300 | 2.10 | EPA 4584799 → |
TCFY2417STANM+ furnace: S921V0403A17M4SCold climate designationAHRI reference: 218327301 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584800 → |
TCFY2417STANM+ furnace: S802V1004A17UHSCold climate designationAHRI reference: 218327300 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584801 → |
TCFY2417STANM+ furnace: S802V1004A17UHNCold climate designationAHRI reference: 218327299 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584802 → |
TCFY2417STANM+ furnace: S802V0754A17UHSCold climate designationAHRI reference: 218327298 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584803 → |
TCFY2417STANM+ furnace: S802V0754A17UHNCold climate designationAHRI reference: 218327297 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584804 → |
TCFY2417STANM+ furnace: S802V0754A17DZSCold climate designationAHRI reference: 218327296 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584805 → |
TCFY2417STANM+ furnace: S802V0754A17DZNCold climate designationAHRI reference: 218327295 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584806 → |
TCFY2417STANM+ furnace: S802V0504A17UHSCold climate designationAHRI reference: 218327294 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584807 → |
TCFY2417STANM+ furnace: S802V0504A17UHNCold climate designationAHRI reference: 218327293 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584808 → |
TCFY2417STANM+ furnace: S802V0503A14UHSCold climate designationAHRI reference: 218327292 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584809 → |
TCFY2417STANM+ furnace: S802V0503A14UHNCold climate designationAHRI reference: 218327291 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584810 → |
TCFY2417STANM+ furnace: S802V0503A14DZSCold climate designationAHRI reference: 218327290 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584811 → |
TCFY2417STANM+ furnace: S802V0503A14DZNCold climate designationAHRI reference: 218327289 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584812 → |
TCFY2417STANM+ furnace: S801V1004A17UHSCold climate designationAHRI reference: 218327288 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584813 → |
TCFY2417STANM+ furnace: S801V1004A17UHNCold climate designationAHRI reference: 218327287 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584814 → |
TCFY2417STANM+ furnace: S801V0754A17UHSCold climate designationAHRI reference: 218327286 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584815 → |
TCFY2417STANM+ furnace: S801V0754A17UHNCold climate designationAHRI reference: 218327285 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584816 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →