Heating performance & equipment details
Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–20 | 192 / 192 |
| EER2 · BTU/Wh | 11.7–13 | 192 / 192 |
| HSPF2 · BTU/Wh | 8.1–10 | 192 / 192 |
| Cooling capacity · BTU/h | 31,000–32,800 | 192 / 192 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,000–36,000 | 192 / 192 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,000–31,000 | 192 / 192 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,600–28,200 | 192 / 192 |
| COP at 5°F / −15°C | 1.9–2.2 | 192 / 192 |
| Equipment / loop type | HP - Split System | 192 / 192 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 192 / 192 |
| Compressor staging | Continuously variable | 192 / 192 |
| Connected capability | Yes | 192 / 192 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY3621STANM+ furnace: S951V0705A21M4Cold climate designationAHRI reference: 216891962 | 18.00 | 8.50 | 27600 | 1.90 | EPA 3994821 → |
TCFY3617STANM+ furnace: S921V0703A17M4Cold climate designationAHRI reference: 216891964 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994822 → |
TCFY3617STANM+ furnace: S962V0703A17M4Cold climate designationAHRI reference: 216891967 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994826 → |
TCFY3621STANM+ furnace: S802V0504A17UHCold climate designationAHRI reference: 216891971 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994830 → |
TCFY3621STANM+ furnace: S921V0705A21M4Cold climate designationAHRI reference: 216891972 | 18.00 | 8.50 | 27600 | 1.90 | EPA 3994831 → |
TCFY3617STANM+ furnace: S801V0504A17UHSCold climate designationAHRI reference: 216891978 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994838 → |
TCFY3617STANM+ furnace: S921V0403A17M4Cold climate designationAHRI reference: 216891982 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994854 → |
TCFY3617STANM+ furnace: S951V0703A17M4Cold climate designationAHRI reference: 216891984 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994856 → |
TCFY3621STANM+ furnace: S801V0504A17UHSCold climate designationAHRI reference: 216891985 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994857 → |
TCFY3617STANM+ furnace: S962V0603A17M4Cold climate designationAHRI reference: 216891986 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994858 → |
TCFY3617STANM+ furnace: S951V0603A17M4Cold climate designationAHRI reference: 216891987 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994859 → |
TCFY3621STANM+ furnace: S801V0704A17UHCold climate designationAHRI reference: 216891988 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994860 → |
TCFY3621STANM+ furnace: S97MV0703A17DHCold climate designationAHRI reference: 216891994 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994866 → |
TCFY3621STANM+ furnace: S921V0403A17M4Cold climate designationAHRI reference: 216891996 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994867 → |
TCFY3617STANM+ furnace: S97MV0703A17DHCold climate designationAHRI reference: 216891995 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994868 → |
TCFY3617STANM+ furnace: S802V0503A14DZCold climate designationAHRI reference: 216891997 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994869 → |
TCFY3621STANM+ furnace: S962V0703A17M4Cold climate designationAHRI reference: 216891998 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994870 → |
TCFY3621STANM+ furnace: S801V0504A17UHNCold climate designationAHRI reference: 216891999 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994871 → |
TCFY3621STANM+ furnace: S951V0603A17M4Cold climate designationAHRI reference: 216892009 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3994872 → |
TCFY3621STANM+ furnace: S951V0403A17UHCold climate designationAHRI reference: 216892000 | 18.00 | 8.50 | 28000 | 1.90 | EPA 3994873 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.