52 published source records · source checked Sep 21, 2026

SEER2 range17–19BTU/Wh
HSPF2 range8.1–10BTU/Wh
Cooling capacity20,800–21,400BTU/h

Each efficiency range summarizes published EPA records for RD18AY24AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 52 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–1952 / 52
EER2 · BTU/Wh10–1252 / 52
HSPF2 · BTU/Wh8.1–1052 / 52
Cooling capacity · BTU/h20,800–21,40052 / 52
Heating capacity at 47°F / 8.3°C · BTU/h20,600–24,00052 / 52
Heating capacity at 17°F / −8.3°C · BTU/h17,900–19,70052 / 52
Heating capacity at 5°F / −15°C · BTU/h16,800–18,30052 / 52
COP at 5°F / −15°C1.9–252 / 52
Equipment / loop typeHP - Split System52 / 52
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)52 / 52
Compressor stagingContinuously variable52 / 52
Connected capabilityYes52 / 52

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
TCFY2417MTANM+ furnace: S951V0603A17UHCold climate designationAHRI reference: 21682067917.009.50171001.90EPA 4028193
TCFY2417MTANM+ furnace: S951V0403A17M4Cold climate designationAHRI reference: 21682068117.009.50170001.90EPA 4028194
TCFY2417MTANM+ furnace: S801V0504A17UHUCold climate designationAHRI reference: 21682068317.009.50171001.90EPA 4028195
TCFY2421MTANM+ furnace: S962V0403A17M4Cold climate designationAHRI reference: 21682075917.009.50170001.90EPA 4028295
TCFY2421MTANM+ furnace: S921V0403A17M4Cold climate designationAHRI reference: 21682076317.009.50170001.90EPA 4028296
TCFY2421MTANM+ furnace: S921V0603A17M4Cold climate designationAHRI reference: 21682076617.009.50171001.90EPA 4028298
TCFY2421MTANM+ furnace: S951V0403A17M4Cold climate designationAHRI reference: 21682076817.009.50170001.90EPA 4028299
TCFY2421MTANM+ furnace: S951V0603A17UHCold climate designationAHRI reference: 21682077517.009.50171001.90EPA 4028300
TCFY2421MTANM+ furnace: S801V0504A17UHUCold climate designationAHRI reference: 21682077817.009.50171001.90EPA 4028302
TCFY2417MTANM+ furnace: S962V0703A17M4Cold climate designationAHRI reference: 21682070917.008.10170001.90EPA 4028556
TCFY2421MTANM+ furnace: S962V0703A17M4Cold climate designationAHRI reference: 21682077217.008.10170001.90EPA 4028559
RF2TY2421STANSCold climate designationAHRI reference: 21871844117.008.10170002.00EPA 4691712

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.