R5H5S24*K*AAA*
15 SEER2 HP · source records, page 3
170 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for R5H5S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 170 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.5 | 170 / 170 |
| EER2 · BTU/Wh | 11.7–13 | 170 / 170 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 170 / 170 |
| Cooling capacity · BTU/h | 22,200–24,400 | 170 / 170 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 21,600–23,800 | 170 / 170 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,200–15,200 | 170 / 170 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,800–11,900 | 170 / 170 |
| COP at 5°F / −15°C | 1.96–2.26 | 170 / 170 |
| Equipment / loop type | HP - Split System | 170 / 170 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 170 / 170 |
| Compressor staging | Single stage | 170 / 170 |
| Connected capability | No | 170 / 170 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X25M17A*+ furnace: *80CTL0451712B*AHRI reference: 214197560 | 15.50 | 7.80 | 11500 | 2.10 | EPA 3405634 → |
EA*5X25M17A*+ furnace: *96MSN0601716A*AHRI reference: 214198043 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3405781 → |
EA*5X25M17A*+ furnace: *96MSM0601716A*AHRI reference: 214198044 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3405782 → |
EA*5X25M17A*+ furnace: *95CSU0601716B*AHRI reference: 214197748 | 15.50 | 7.80 | 11300 | 2.10 | EPA 3405839 → |
EA*5X25M17A*+ furnace: *97CMN0601714B*AHRI reference: 214197829 | 15.50 | 7.80 | 11500 | 2.10 | EPA 3405969 → |
EA*5X25M17A*+ furnace: *97CMN0801714B*AHRI reference: 214197856 | 15.50 | 7.80 | 11500 | 2.12 | EPA 3405995 → |
EVM5X32M17A*+ furnace: *96VSN0601716B*AHRI reference: 214204692 | 15.50 | 7.80 | 11400 | 1.98 | EPA 3406286 → |
EVM5X32M17A*+ furnace: *96VSN0801716B*AHRI reference: 214204717 | 15.50 | 7.80 | 11300 | 1.98 | EPA 3406309 → |
EVD5X31M17A*+ furnace: *95MSU0601716A*AHRI reference: 214205619 | 15.50 | 7.80 | 11300 | 1.98 | EPA 3406340 → |
EA*5X37M21A*+ furnace: *80CTL0901716B*AHRI reference: 214201943 | 15.50 | 7.80 | 11500 | 2.14 | EPA 3406404 → |
EA*5X37M21A*+ furnace: *80CTL1102120B*AHRI reference: 214201970 | 15.50 | 7.80 | 11600 | 2.14 | EPA 3406439 → |
EA*5X37M21A*+ furnace: *97CMN0601714B*AHRI reference: 214202319 | 15.50 | 7.80 | 11700 | 2.12 | EPA 3406448 → |
EA*5X37M21A*+ furnace: *95MSU0802120A*AHRI reference: 214202856 | 15.50 | 7.80 | 11600 | 2.14 | EPA 3406569 → |
EA*5X37M17A*+ furnace: *80CSU0401712A*AHRI reference: 214199457 | 15.50 | 7.80 | 11200 | 2.08 | EPA 3406669 → |
EA*5X37M21A*+ furnace: *80VTL0902120B*AHRI reference: 214202076 | 15.50 | 7.80 | 11600 | 2.14 | EPA 3406795 → |
EA*5X37M21A*+ furnace: *96CTN0601714B*AHRI reference: 214202964 | 15.50 | 7.80 | 11600 | 2.12 | EPA 3406796 → |
EA*5X37M21A*+ furnace: *80CSU1002120A*AHRI reference: 214201362 | 15.50 | 7.80 | 11500 | 2.12 | EPA 3406836 → |
EA*5X37M21A*+ furnace: *80CSU0601716A*AHRI reference: 214201335 | 15.50 | 7.80 | 11300 | 2.12 | EPA 3406934 → |
EA*5X37M21A*+ furnace: *95CSU0601716B*AHRI reference: 214202157 | 15.50 | 7.80 | 11600 | 2.14 | EPA 3406976 → |
EA*5X37M21A*+ furnace: *95CSU0802120B*AHRI reference: 214202184 | 15.50 | 7.80 | 11600 | 2.14 | EPA 3407027 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →