SMART COMFORT / AIR-SOURCE HEAT PUMP

R5H5S24*K*AAA*

15 SEER2 HP

170 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for R5H5S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 170 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5170 / 170
EER2 · BTU/Wh11.7–13170 / 170
HSPF2 · BTU/Wh7.8–8.5170 / 170
Cooling capacity · BTU/h22,200–24,400170 / 170
Heating capacity at 47°F / 8.3°C · BTU/h21,600–23,800170 / 170
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200170 / 170
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900170 / 170
COP at 5°F / −15°C1.96–2.26170 / 170
Equipment / loop typeHP - Split System170 / 170
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)170 / 170
Compressor stagingSingle stage170 / 170
Connected capabilityNo170 / 170

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FMA5X30**AL*AHRI reference: 21442409416.508.50116002.26EPA 3425101
EVD5X31M17A*+ furnace: *80VSL0901716B*AHRI reference: 21420507516.007.80113001.98EPA 3408547
EVM5X32M17A*+ furnace: *80MSU0601716A*AHRI reference: 21421275616.007.80113002.00EPA 3409005
EVD5X38M17A*+ furnace: *80VTL0701716B*AHRI reference: 21421437416.007.80114002.00EPA 3409029
EA*5X37M21A*+ furnace: *80CSU0401712A*AHRI reference: 21421090016.007.80112002.12EPA 3409105
EA*5X37M21A*+ furnace: *80CSU0802120A*AHRI reference: 21421092716.007.80113002.14EPA 3409132
EVM5X32M17A*+ furnace: *80VSL0901716B*AHRI reference: 21421266216.007.80114001.98EPA 3409266
EVD5X38M17A*+ furnace: *92MSN0601714A*AHRI reference: 21421450316.007.80114002.00EPA 3409283
EA*5X37M21A*+ furnace: *95MSU1002120A*AHRI reference: 21421198816.007.80115002.14EPA 3409837
EVM5X32M17A*+ furnace: *92MSN0801716A*AHRI reference: 21421301616.007.80112001.98EPA 3410028
EA*5X37M21A*+ furnace: *96CTN1002122A*AHRI reference: 21421204016.007.80112002.12EPA 3410097
EA*5X37M21A*+ furnace: *96CTN0802120B*AHRI reference: 21421206716.007.80114001.96EPA 3410125
EA*5X37M21A*+ furnace: *96CTN1002122B*AHRI reference: 21421209416.007.80115002.14EPA 3410151
EA*5X25M17A*+ furnace: *80MSU0401712A*AHRI reference: 21421054816.007.80113002.12EPA 3410519
EA*5X25M17A*+ furnace: *80MSU0601716A*AHRI reference: 21421058016.007.80112002.12EPA 3410551
EA*5X37M21A*+ furnace: *80CTL0902120B*AHRI reference: 21421144716.007.80115002.14EPA 3410694
EA*5X37M21A*+ furnace: *80VTL1102122B*AHRI reference: 21421150516.007.80115002.14EPA 3410758
EVD5X38M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21421402316.007.80114002.00EPA 3410781
EVM5X31M17A*+ furnace: *80MSU0601716A*AHRI reference: 21421236816.007.80112001.98EPA 3410832
EA*5X25M17A*+ furnace: *80CTL0701412B*AHRI reference: 21421063616.007.80114002.12EPA 3410910