SMART COMFORT / AIR-SOURCE HEAT PUMP

N5H5S24*K*AAA*

PERFORMANCE 16 SEER2 HP · source records, page 8

170 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for N5H5S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 170 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5170 / 170
EER2 · BTU/Wh11.7–13170 / 170
HSPF2 · BTU/Wh7.8–8.5170 / 170
Cooling capacity · BTU/h22,200–24,400170 / 170
Heating capacity at 47°F / 8.3°C · BTU/h21,600–23,800170 / 170
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200170 / 170
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900170 / 170
COP at 5°F / −15°C1.96–2.26170 / 170
Equipment / loop typeHP - Split System170 / 170
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)170 / 170
Compressor stagingSingle stage170 / 170
Connected capabilityNo170 / 170

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M17A*+ furnace: *96VTN0601716B*AHRI reference: 21420124515.207.80114002.08EPA 3406478
EA*5X37M17A*+ furnace: *96VTN0801716B*AHRI reference: 21420127815.207.80114002.08EPA 3406510
EA*5X37M17A*+ furnace: *80VTL0701716B*AHRI reference: 21420038015.207.80113002.08EPA 3406684
EA*5X37M17A*+ furnace: *80VTL0451412B*AHRI reference: 21420033815.207.80112002.08EPA 3406741
EA*5X37M17A*+ furnace: *80MS(N,L)0451412A*AHRI reference: 21419971515.207.80113002.08EPA 3407198
EA*5X37M21A*+ furnace: *96VTN0601716B*AHRI reference: 21420317715.207.80118002.12EPA 3407457
EA*5X37M21A*+ furnace: *96VTN0801716B*AHRI reference: 21420320815.207.80116002.12EPA 3407489
EA*5X37M21A*+ furnace: *96MSN0801716A*AHRI reference: 21420252515.207.80116002.12EPA 3407890
EA*5X37M21A*+ furnace: *96MSN0601716A*AHRI reference: 21420249315.207.80117002.12EPA 3407964
EA*5X37M21A*+ furnace: *96MSM0601716A*AHRI reference: 21420249415.207.80117002.12EPA 3407966
EA*5X37M17A*+ furnace: *80VSL0451412B*AHRI reference: 21419994915.207.80112002.08EPA 3407996
EA*5X37M17A*+ furnace: *80VSL0701412B*AHRI reference: 21419997415.207.80112002.08EPA 3408022
EA*5X37M17A*+ furnace: *80VSL0701716B*AHRI reference: 21419999915.207.80113002.08EPA 3408047
EA*5X37M17A*+ furnace: *96MSN0601716A*AHRI reference: 21420080415.207.80114002.08EPA 3408061
EA*5X37M17A*+ furnace: *96MSM0601716A*AHRI reference: 21420080515.207.80114002.08EPA 3408063
EA*5X37M21A*+ furnace: *96VSN0801716B*AHRI reference: 21420274015.207.80116002.12EPA 3408284
EA*5X37M17A*+ furnace: *96VSN0601716B*AHRI reference: 21420091915.207.80114002.08EPA 3408332
EA*5X37M17A*+ furnace: *96VSN0801716B*AHRI reference: 21420094415.207.80114002.08EPA 3408359
EA*5X37M21A*+ furnace: *80VSL0701716B*AHRI reference: 21420167315.207.80115002.14EPA 3408371
EA*5X37M21A*+ furnace: *80VSL0901716B*AHRI reference: 21420169815.207.80116002.14EPA 3408397

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →