SMART COMFORT / AIR-SOURCE HEAT PUMP

N5H5S18*K*AAA*

PERFORMANCE 16 SEER2 HP

44 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,400–18,900BTU/h

Each efficiency range summarizes published EPA records for N5H5S18*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 44 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.544 / 44
EER2 · BTU/Wh11.7–12.544 / 44
HSPF2 · BTU/Wh7.8–844 / 44
Cooling capacity · BTU/h17,400–18,90044 / 44
Heating capacity at 47°F / 8.3°C · BTU/h16,400–18,30044 / 44
Heating capacity at 17°F / −8.3°C · BTU/h10,500–11,00044 / 44
Heating capacity at 5°F / −15°C · BTU/h8,200–8,60044 / 44
COP at 5°F / −15°C1.88–2.144 / 44
Equipment / loop typeHP - Split System44 / 44
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)44 / 44
Compressor stagingSingle stage44 / 44
Connected capabilityNo44 / 44

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X32M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21419548615.507.8082001.94EPA 3405060 →
FMA5X24**AL*AHRI reference: 21442394115.508.0082002.10EPA 3425263 →
EA*5X19M17A*+ furnace: *80MS(N,L)0451412A*AHRI reference: 21412479115.207.8084002.02EPA 3398545 →
EA*5X19M17A*+ furnace: *80MS(N,L)0701412A*AHRI reference: 21412482115.207.8084002.04EPA 3398575 →
EA*5X25M17A*+ furnace: *80MS(N,L)0451412A*AHRI reference: 21412610415.207.8084002.04EPA 3398634 →
EA*5X25M17A*+ furnace: *80VTL0451412B*AHRI reference: 21412669115.207.8084002.04EPA 3398656 →
EA*5X25M17A*+ furnace: *80MS(N,L)0701412A*AHRI reference: 21412616415.207.8084002.06EPA 3398721 →
EA*5X25M17A*+ furnace: *80VTL0701716B*AHRI reference: 21412673315.207.8085002.04EPA 3398786 →
EA*5X25M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21412622615.207.8085002.06EPA 3398805 →
EA*5X25M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 21412625815.207.8084002.04EPA 3398837 →
EA*5X19M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21412487915.207.8084002.04EPA 3398879 →
EA*5X19M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 21412490915.207.8084002.04EPA 3398915 →
EA*5X25M17A*+ furnace: *92MSN0801716A*AHRI reference: 21412703415.207.8084002.06EPA 3398961 →
EA*5X19M17A*+ furnace: *92MSN0801716A*AHRI reference: 21412558015.207.8084002.04EPA 3398970 →
EA*5X25M17A*+ furnace: *80VSL0701716B*AHRI reference: 21412636215.207.8084002.04EPA 3398981 →
EA*5X25M17A*+ furnace: *80ESU0401712A*AHRI reference: 21412641715.207.8084002.06EPA 3399011 →
EA*5X25M17A*+ furnace: *80MSU0401712A*AHRI reference: 21412648115.207.8084002.06EPA 3399075 →
EA*5X25M17A*+ furnace: *96MSN0801716A*AHRI reference: 21412709815.207.8085002.04EPA 3399116 →
EA*5X19M17A*+ furnace: *95MSU0601716A*AHRI reference: 21412577915.207.8084002.04EPA 3399148 →
EA*5X25M17A*+ furnace: *80MSU0601716A*AHRI reference: 21412651315.207.8084002.06EPA 3399162 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →