Each efficiency range summarizes published EPA records for D5CUHAH36AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 320 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 320 / 320 |
| EER2 · BTU/Wh | 9.4–10.5 | 320 / 320 |
| HSPF2 · BTU/Wh | 8.1–9 | 320 / 320 |
| Cooling capacity · BTU/h | 34,200–38,000 | 320 / 320 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,400–40,000 | 320 / 320 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–26,200 | 320 / 320 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,800–31,600 | 320 / 320 |
| COP at 5°F / −15°C | 1.75–1.9 | 320 / 320 |
| Equipment / loop type | HP - Split System | 320 / 320 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 320 / 320 |
| Compressor staging | Continuously variable | 320 / 320 |
| Connected capability | No | 320 / 320 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
ESH5X48M12A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 218681875 | 16.00 | 8.10 | 30600 | 1.75 | EPA 4671818 → |
ESH5X48M12A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 218681871 | 16.00 | 8.10 | 30600 | 1.75 | EPA 4671820 → |
ESH5X48M12A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 218681866 | 16.00 | 8.10 | 30400 | 1.75 | EPA 4671825 → |
ESH5X48M12A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 218681865 | 16.00 | 8.10 | 30400 | 1.75 | EPA 4671826 → |
ESH5X48M12A*+ furnace: *80VSL1352422B*Cold climate designationAHRI reference: 218681863 | 16.00 | 8.10 | 30400 | 1.75 | EPA 4671828 → |
ESH5X48M12A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 218681862 | 16.00 | 8.10 | 30400 | 1.75 | EPA 4671829 → |
EA*5X48M21A*+ furnace: *96MSN1002120A*Cold climate designationAHRI reference: 218682887 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4671394 → |
EA*5X48M21A*+ furnace: *92MSN0601714A*Cold climate designationAHRI reference: 218682884 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4671397 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0902116A*Cold climate designationAHRI reference: 218682883 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4671398 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0702116A*Cold climate designationAHRI reference: 218682882 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4671399 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0701716A*Cold climate designationAHRI reference: 218682881 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4671400 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 218682880 | 15.50 | 8.10 | 30000 | 1.75 | EPA 4671401 → |
EA*5X48M21A*+ furnace: *96MSN1002122A*Cold climate designationAHRI reference: 218682334 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4671527 → |
EA*5X43M21A*+ furnace: *96MSN1002122A*Cold climate designationAHRI reference: 218682333 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4671528 → |
EA*5X42M21A*+ furnace: *96MSN1002122A*Cold climate designationAHRI reference: 218682332 | 15.50 | 8.50 | 30800 | 1.80 | EPA 4671529 → |
EA*5X37M21A*+ furnace: *96MSN1002122A*Cold climate designationAHRI reference: 218682331 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4671530 → |
EA*5X43M21A*+ furnace: *96MSN1002120A*Cold climate designationAHRI reference: 218682327 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4671531 → |
EA*5X42M21A*+ furnace: *96MSN1002120A*Cold climate designationAHRI reference: 218682326 | 15.50 | 8.50 | 30800 | 1.78 | EPA 4671532 → |
EA*5X37M21A*+ furnace: *96MSN1002120A*Cold climate designationAHRI reference: 218682325 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4671533 → |
EA*5X43M21A*+ furnace: *96MSM0802120A*Cold climate designationAHRI reference: 218682316 | 15.50 | 8.50 | 30200 | 1.84 | EPA 4671536 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.