D5CUHAH36AAK+KSAIC0701230
Crossover Heat Pump · source records, page 10
320 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH36AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 320 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 320 / 320 |
| EER2 · BTU/Wh | 9.4–10.5 | 320 / 320 |
| HSPF2 · BTU/Wh | 8.1–9 | 320 / 320 |
| Cooling capacity · BTU/h | 34,200–38,000 | 320 / 320 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,400–40,000 | 320 / 320 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–26,200 | 320 / 320 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,800–31,600 | 320 / 320 |
| COP at 5°F / −15°C | 1.75–1.9 | 320 / 320 |
| Equipment / loop type | HP - Split System | 320 / 320 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 320 / 320 |
| Compressor staging | Continuously variable | 320 / 320 |
| Connected capability | No | 320 / 320 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X36M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 218682147 | 15.50 | 8.10 | 31000 | 1.75 | EPA 4671608 → |
EA*5X36M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 218682146 | 15.50 | 8.10 | 31000 | 1.75 | EPA 4671609 → |
EA*5X36M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 218682145 | 15.50 | 8.10 | 31000 | 1.75 | EPA 4671610 → |
EA*5X36M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 218682144 | 15.50 | 8.10 | 31000 | 1.75 | EPA 4671611 → |
EA*5X36M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 218682143 | 15.50 | 8.10 | 31000 | 1.75 | EPA 4671612 → |
EA*5X37M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218682141 | 15.50 | 8.50 | 30800 | 1.84 | EPA 4671614 → |
EA*5X37M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218682140 | 15.50 | 8.50 | 30800 | 1.84 | EPA 4671615 → |
EA*5X37M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218682139 | 15.50 | 8.50 | 30800 | 1.84 | EPA 4671616 → |
EA*5X37M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218682138 | 15.50 | 8.50 | 30800 | 1.84 | EPA 4671617 → |
EA*5X37M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 218682135 | 15.50 | 8.50 | 30600 | 1.84 | EPA 4671618 → |
EA*5X37M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 218682133 | 15.50 | 8.50 | 30800 | 1.84 | EPA 4671620 → |
EA*5X37M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218682132 | 15.50 | 8.50 | 30800 | 1.84 | EPA 4671621 → |
EA*5X37M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 218682129 | 15.50 | 8.50 | 30600 | 1.82 | EPA 4671622 → |
EA*5X37M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 218682128 | 15.50 | 8.50 | 30600 | 1.82 | EPA 4671623 → |
EA*5X37M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 218682125 | 15.50 | 8.50 | 30600 | 1.84 | EPA 4671626 → |
EA*5X37M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 218682124 | 15.50 | 8.50 | 30600 | 1.82 | EPA 4671627 → |
EA*5X37M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 218682123 | 15.50 | 8.50 | 30600 | 1.82 | EPA 4671628 → |
EA*5X37M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 218682122 | 15.50 | 8.50 | 30600 | 1.82 | EPA 4671629 → |
EA*5X37M21A*+ furnace: OMV098J12*Cold climate designationAHRI reference: 218682120 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4671630 → |
EA*5X37M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218682114 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4671635 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.