SEER2 range15.2–17BTU/Wh
HSPF2 range8.1–9BTU/Wh
Cooling capacity28,600–31,200BTU/h

Each efficiency range summarizes published EPA records for D5CUHAH30AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 342 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17342 / 342
EER2 · BTU/Wh9.5–10.5342 / 342
HSPF2 · BTU/Wh8.1–9342 / 342
Cooling capacity · BTU/h28,600–31,200342 / 342
Heating capacity at 47°F / 8.3°C · BTU/h35,800–37,400342 / 342
Heating capacity at 17°F / −8.3°C · BTU/h20,800–21,600342 / 342
Heating capacity at 5°F / −15°C · BTU/h32,000–33,400342 / 342
COP at 5°F / −15°C1.75–2342 / 342
Equipment / loop typeHP - Split System342 / 342
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)342 / 342
Compressor stagingContinuously variable342 / 342
Connected capabilityNo342 / 342

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X42M21A*+ furnace: *96MSM0802120A*Cold climate designationAHRI reference: 21868164215.508.50330001.80EPA 4671977
EA*5X42M21A*+ furnace: *96MSN0802120A*Cold climate designationAHRI reference: 21868164115.508.50330001.80EPA 4671978
EA*5X42M21A*+ furnace: *96MSN0801716A*Cold climate designationAHRI reference: 21868164015.508.50330001.80EPA 4671979
EA*5X42M21A*+ furnace: *92MSN1002122A*Cold climate designationAHRI reference: 21868163715.508.50328001.80EPA 4671982
EA*5X42M21A*+ furnace: *92MSN1002120A*Cold climate designationAHRI reference: 21868163615.508.50328001.80EPA 4671983
EA*5X42M21A*+ furnace: *92MSN0802120A*Cold climate designationAHRI reference: 21868163515.508.50328001.80EPA 4671984
EA*5X42M21A*+ furnace: *92MSN0801716A*Cold climate designationAHRI reference: 21868163415.508.50328001.80EPA 4671985
EA*5X42M21A*+ furnace: *92MSN0601714A*Cold climate designationAHRI reference: 21868163315.508.50330001.80EPA 4671986
EA*5X42M21A*+ furnace: *80MS(N,L)1102120A*Cold climate designationAHRI reference: 21868162115.508.50328001.80EPA 4671998
EA*5X42M21A*+ furnace: *80MS(N,L)0902120A*Cold climate designationAHRI reference: 21868162015.508.50328001.80EPA 4671999
EA*5X42M21A*+ furnace: *80MS(N,L)0902116A*Cold climate designationAHRI reference: 21868161915.508.50330001.78EPA 4672000
EA*5X42M21A*+ furnace: *80MS(N,L)0901714A*Cold climate designationAHRI reference: 21868161815.508.50328001.80EPA 4672001
EA*5X42M21A*+ furnace: *80MS(N,L)0702116A*Cold climate designationAHRI reference: 21868161715.508.50328001.80EPA 4672002
EA*5X42M21A*+ furnace: *80MS(N,L)0701716A*Cold climate designationAHRI reference: 21868161615.508.50328001.80EPA 4672003
EA*5X42M21A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 21868161515.508.50328001.80EPA 4672004
EA*5X43M21A*+ furnace: OLV112A16ACold climate designationAHRI reference: 21868161115.509.00322002.00EPA 4672007
EA*5X43M21A*+ furnace: *96VTN0401712B*Cold climate designationAHRI reference: 21868159915.509.00324001.96EPA 4672018
EA*5X43M21A*+ furnace: *96VSN0401712B*Cold climate designationAHRI reference: 21868158915.509.00324001.96EPA 4672028
EA*5X43M21A*+ furnace: *96MSN1002122A*Cold climate designationAHRI reference: 21868158815.509.00322001.98EPA 4672029
EA*5X43M21A*+ furnace: *96MSM0802120A*Cold climate designationAHRI reference: 21868158615.509.00322001.96EPA 4672031

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.