D5CUHAH30AAK+KSAIC0701230
Crossover Heat Pump
342 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH30AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 342 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 342 / 342 |
| EER2 · BTU/Wh | 9.5–10.5 | 342 / 342 |
| HSPF2 · BTU/Wh | 8.1–9 | 342 / 342 |
| Cooling capacity · BTU/h | 28,600–31,200 | 342 / 342 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 35,800–37,400 | 342 / 342 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,800–21,600 | 342 / 342 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–33,400 | 342 / 342 |
| COP at 5°F / −15°C | 1.75–2 | 342 / 342 |
| Equipment / loop type | HP - Split System | 342 / 342 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 342 / 342 |
| Compressor staging | Continuously variable | 342 / 342 |
| Connected capability | No | 342 / 342 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FTMA5B36L0C*Cold climate designationAHRI reference: 218680172 | 17.00 | 8.50 | 32800 | 1.78 | EPA 4671391 → |
EA*5X37M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 218681684 | 17.00 | 9.00 | 32000 | 1.98 | EPA 4671939 → |
EA*5X43M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 218681572 | 17.00 | 9.00 | 32000 | 1.98 | EPA 4672045 → |
EA*5X37M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 218681721 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4671902 → |
EA*5X37M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 218681720 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4671903 → |
EA*5X37M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 218681719 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4671904 → |
EA*5X37M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 218681716 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4671907 → |
EA*5X37M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 218681715 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4671908 → |
EA*5X37M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 218681714 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4671909 → |
EA*5X37M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 218681710 | 16.50 | 9.00 | 32200 | 1.98 | EPA 4671913 → |
EA*5X37M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 218681709 | 16.50 | 9.00 | 32200 | 1.98 | EPA 4671914 → |
EA*5X37M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 218681705 | 16.50 | 9.00 | 32200 | 1.98 | EPA 4671918 → |
EA*5X37M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 218681704 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4671919 → |
EA*5X37M21A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 218681688 | 16.50 | 9.00 | 32200 | 1.98 | EPA 4671935 → |
EA*5X37M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 218681686 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4671937 → |
EA*5X37M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 218681683 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4671940 → |
EA*5X37M21A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 218681682 | 16.50 | 9.00 | 32200 | 1.98 | EPA 4671941 → |
EA*5X37M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 218681681 | 16.50 | 9.00 | 32200 | 1.98 | EPA 4671942 → |
EA*5X37M21A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 218681679 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4671944 → |
EA*5X42M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 218681664 | 16.50 | 8.50 | 32800 | 1.80 | EPA 4671957 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.