SMART COMFORT / AIR-SOURCE HEAT PUMP

D5CUHAH24AAK+KSAIC0701230

Crossover Heat Pump · source records, page 8

511 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity22,600–25,000BTU/h

Each efficiency range summarizes published EPA records for D5CUHAH24AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 511 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18511 / 511
EER2 · BTU/Wh10–11511 / 511
HSPF2 · BTU/Wh8.1–9.5511 / 511
Cooling capacity · BTU/h22,600–25,000511 / 511
Heating capacity at 47°F / 8.3°C · BTU/h22,200–25,800511 / 511
Heating capacity at 17°F / −8.3°C · BTU/h16,800–18,700511 / 511
Heating capacity at 5°F / −15°C · BTU/h18,700–20,600511 / 511
COP at 5°F / −15°C1.85–2.06511 / 511
Equipment / loop typeHP - Split System511 / 511
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)511 / 511
Compressor stagingContinuously variable511 / 511
Connected capabilityNo511 / 511

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X25M17A*+ furnace: *96VSN0401410B*Cold climate designationAHRI reference: 21868106116.508.50190001.92EPA 4671077
EA*5X24M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 21868104916.509.00198002.00EPA 4671089
EA*5X24M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 21868104816.509.00198001.98EPA 4671090
EA*5X24M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 21868104716.509.00198002.00EPA 4671091
EA*5X24M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 21868104616.509.00198001.98EPA 4671092
EA*5X24M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 21868104516.509.00198002.00EPA 4671093
EA*5X24M17A*+ furnace: *96VTN0401712B*Cold climate designationAHRI reference: 21868104416.509.00200002.00EPA 4671094
EA*5X24M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 21868104216.509.00198001.98EPA 4671096
EA*5X24M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 21868104116.509.00198001.98EPA 4671097
EA*5X24M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 21868104016.509.00198002.00EPA 4671098
EA*5X24M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 21868103916.509.00198001.98EPA 4671099
EA*5X24M17A*+ furnace: *96VSN0601412B*Cold climate designationAHRI reference: 21868103816.509.00198002.00EPA 4671100
EA*5X24M17A*+ furnace: *96VSN0401712B*Cold climate designationAHRI reference: 21868103716.509.00200002.00EPA 4671101
EA*5X24M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 21868103516.509.00198001.98EPA 4671103
EA*5X24M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 21868103416.509.00198002.00EPA 4671104
EA*5X24M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 21868103316.509.00198002.00EPA 4671105
EA*5X24M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 21868103116.509.00198002.00EPA 4671107
EA*5X24M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 21868103016.509.00198001.98EPA 4671108
EA*5X24M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 21868102816.509.00198002.00EPA 4671110
EA*5X24M14A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 21868102316.509.00198002.00EPA 4671115

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →