D5CUHAH24AAK+KSAIC0701230
Crossover Heat Pump · source records, page 16
511 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH24AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 511 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 511 / 511 |
| EER2 · BTU/Wh | 10–11 | 511 / 511 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 511 / 511 |
| Cooling capacity · BTU/h | 22,600–25,000 | 511 / 511 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–25,800 | 511 / 511 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–18,700 | 511 / 511 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,600 | 511 / 511 |
| COP at 5°F / −15°C | 1.85–2.06 | 511 / 511 |
| Equipment / loop type | HP - Split System | 511 / 511 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 511 / 511 |
| Compressor staging | Continuously variable | 511 / 511 |
| Connected capability | No | 511 / 511 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X24M17A*+ furnace: *80MS(N,L)0451412A*Cold climate designationAHRI reference: 218680778 | 16.00 | 8.50 | 19800 | 1.92 | EPA 4671317 → |
EA*5X24M14A*+ furnace: *96MSN0601412A*Cold climate designationAHRI reference: 218680777 | 16.00 | 8.50 | 19800 | 1.92 | EPA 4671318 → |
EA*5X24M14A*+ furnace: *92MSN0601412A*Cold climate designationAHRI reference: 218680774 | 16.00 | 8.50 | 19800 | 1.92 | EPA 4671321 → |
EA*5X24M14A*+ furnace: *80MS(N,L)0451412A*Cold climate designationAHRI reference: 218680771 | 16.00 | 8.50 | 19800 | 1.90 | EPA 4671323 → |
ESH5X36M12A*+ furnace: *97VTN1202422A*Cold climate designationAHRI reference: 218681329 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4672181 → |
ESH5X36M12A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 218681328 | 16.00 | 8.50 | 19300 | 1.92 | EPA 4672182 → |
ESH5X36M12A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 218681327 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4672183 → |
ESH5X36M12A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 218681326 | 16.00 | 8.50 | 19300 | 1.92 | EPA 4672184 → |
ESH5X36M12A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218681325 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4672185 → |
ESH5X36M12A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218681324 | 16.00 | 8.50 | 19300 | 1.92 | EPA 4672186 → |
ESH5X36M12A*+ furnace: *96VTN1202422B*Cold climate designationAHRI reference: 218681323 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4672187 → |
ESH5X36M12A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 218681322 | 16.00 | 8.50 | 19300 | 1.92 | EPA 4672188 → |
ESH5X36M12A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 218681321 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4672189 → |
ESH5X36M12A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 218681320 | 16.00 | 8.50 | 19300 | 1.92 | EPA 4672190 → |
ESH5X36M12A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218681319 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4672191 → |
ESH5X36M12A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218681318 | 16.00 | 8.50 | 19300 | 1.92 | EPA 4672192 → |
ESH5X36M12A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 218681317 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4672193 → |
ESH5X36M12A*+ furnace: *96VTN0401712B*Cold climate designationAHRI reference: 218681316 | 16.00 | 8.50 | 19400 | 1.92 | EPA 4672194 → |
ESH5X36M12A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 218681312 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4672198 → |
ESH5X36M12A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 218681311 | 16.00 | 8.50 | 19200 | 1.90 | EPA 4672199 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.