SINCLAIR AIR CONDITIONING / AIR-SOURCE HEAT PUMP

BH714S18P-**A

BH714S Series · source records, page 2

33 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for BH714S18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 33 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.533 / 33
EER2 · BTU/Wh13–14.233 / 33
HSPF2 · BTU/Wh7.833 / 33
Cooling capacity · BTU/h18,00033 / 33
Heating capacity at 47°F / 8.3°C · BTU/h17,500–18,00033 / 33
Heating capacity at 17°F / −8.3°C · BTU/h10,500–11,20033 / 33
Heating capacity at 5°F / −15°C · BTU/h7,900–8,50033 / 33
COP at 5°F / −15°C1.86–233 / 33
Equipment / loop typeHP - Split System33 / 33
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)33 / 33
Compressor stagingSingle stage33 / 33
Connected capabilityNo33 / 33

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC724HBT-**+TDR+ furnace: B97UR702V3BAHRI reference: 21680162616.007.8082001.96EPA 3993055
BC724HAT-**+TDR+ furnace: B80UR702V3AAHRI reference: 21680162416.007.8080001.98EPA 3993121
BC724HBT-**+TDR+ furnace: B80UR902V4BAHRI reference: 21680162516.007.8082001.94EPA 3993122
BC730/36DBT-**+TDR+ furnace: B92DR451E3BAHRI reference: 21637201515.507.8084001.92EPA 3813364
BC730/36DBT-**+TDR+ furnace: B92DR701E3BAHRI reference: 21637201615.507.8084001.94EPA 3813365
BC730/36DBT-**+TDR+ furnace: B96DR451E3BAHRI reference: 21637201715.507.8084001.92EPA 3813367
BC724HAT-**+TDR+ furnace: B80UR401E3AXAHRI reference: 21637197115.507.8080001.94EPA 3813427
BC724HAT-**+TDR+ furnace: B80UR601E3AXAHRI reference: 21637197215.507.8080001.94EPA 3813816
BC730/36DBT-**+TDR+ furnace: B80DR701E3BAHRI reference: 21637201415.207.8084001.90EPA 3813366
BC730/36DBT-**+TDR+ furnace: B96DR701E4BAHRI reference: 21637201815.207.8085001.92EPA 3813368
BC730/36DBT-**+TDR+ furnace: B97DR702E4BAHRI reference: 21637201315.207.8084001.90EPA 3813442
BAH7P24PT-**AHRI reference: 21637193015.207.8084001.98EPA 3813791
BC730/36DBT-**+TDR+ furnace: B97DR452E3BAHRI reference: 21637201215.207.8084001.90EPA 3813818

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →