WP15AY42AJ2N
ACHIEVER PLUS · VERSUS · source records, page 2
72 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for WP15AY42AJ2N. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 72 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 72 / 72 |
| EER2 · BTU/Wh | 11.7 | 72 / 72 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 72 / 72 |
| Cooling capacity · BTU/h | 40,000 | 72 / 72 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 40,000 | 72 / 72 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–40,000 | 72 / 72 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,200–21,000 | 66 / 72 |
| COP at 5°F / −15°C | 2–2.2 | 66 / 72 |
| Equipment / loop type | HP - Split System | 72 / 72 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 72 / 72 |
| Compressor staging | Two-stage | 72 / 72 |
| Connected capability | No | 72 / 72 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFY4821STANM+ furnace: R802V0755A21DZCold climate designationAHRI reference: 215655289 | 15.20 | 8.10 | 18800 | 2.00 | EPA 3645192 → |
RCFY4821STANM+ furnace: R801V0755A21UHCold climate designationAHRI reference: 215655298 | 15.20 | 8.10 | 18900 | 2.00 | EPA 3645199 → |
RCFY4824STANM+ furnace: R801V0755A21DZCold climate designationAHRI reference: 215655320 | 15.20 | 8.10 | 18800 | 2.00 | EPA 3645221 → |
RCFY4821STANM+ furnace: R802V1005A21DZCold climate designationAHRI reference: 215655326 | 15.20 | 8.10 | 18700 | 2.00 | EPA 3645226 → |
RCFY4821STANM+ furnace: R801V1004A17UHCold climate designationAHRI reference: 215655327 | 15.20 | 8.10 | 19000 | 2.00 | EPA 3645229 → |
RCFY4821STANM+ furnace: R801V0754A17DZCold climate designationAHRI reference: 215655350 | 15.20 | 8.10 | 19300 | 2.00 | EPA 3645247 → |
RCFY4824STANM+ furnace: R801V1005A21UHSCold climate designationAHRI reference: 215655365 | 15.20 | 8.10 | 18800 | 2.00 | EPA 3645263 → |
RCFY4821STANM+ furnace: R801V1005A21UHSCold climate designationAHRI reference: 215655393 | 15.20 | 8.10 | 18800 | 2.00 | EPA 3645289 → |
RCFY4824STANM+ furnace: R802V1005A21UHCold climate designationAHRI reference: 215655396 | 15.20 | 8.10 | 18800 | 2.00 | EPA 3645291 → |
RCFY4821STANM+ furnace: R801V1005A21UHUCold climate designationAHRI reference: 215655398 | 15.20 | 8.10 | 18800 | 2.00 | EPA 3645293 → |
RCFY4824STANM+ furnace: R801V1005A21DZCold climate designationAHRI reference: 215655399 | 15.20 | 8.10 | 18700 | 2.00 | EPA 3645294 → |
RCFY4821STANM+ furnace: R802V1004A17UHCold climate designationAHRI reference: 215655406 | 15.20 | 8.10 | 19000 | 2.00 | EPA 3645299 → |
RCFY4824STANM+ furnace: R801V1005A21UHUCold climate designationAHRI reference: 215655404 | 15.20 | 8.10 | 18800 | 2.00 | EPA 3645301 → |
RCFY4821STANM+ furnace: R802V0754A17DZCold climate designationAHRI reference: 215655412 | 15.20 | 8.10 | 19300 | 2.00 | EPA 3645305 → |
RCFY4824STANM+ furnace: R801V1005A21UHNCold climate designationAHRI reference: 215655410 | 15.20 | 8.10 | 18800 | 2.00 | EPA 3645307 → |
RCFY4821STANM+ furnace: R801V0704A17UHCold climate designationAHRI reference: 215655474 | 15.20 | 8.10 | 19300 | 2.00 | EPA 3645349 → |
RCFY4821STANM+ furnace: R801V1005A21UHNCold climate designationAHRI reference: 215655486 | 15.20 | 8.10 | 18800 | 2.00 | EPA 3645359 → |
RCFY4824STANM+ furnace: R802V1005A21DZCold climate designationAHRI reference: 215655431 | 15.20 | 8.10 | 18700 | 2.00 | EPA 3645375 → |
RCFY4821STANM+ furnace: R802V1005A21UHCold climate designationAHRI reference: 215655433 | 15.20 | 8.10 | 18800 | 2.00 | EPA 3645377 → |
RCFY4824STANM+ furnace: R802V1505A24UHCold climate designationAHRI reference: 215655445 | 15.20 | 8.10 | 18800 | 2.00 | EPA 3645387 → |