WP15AY36AJ2N
ACHIEVER PLUS · VERSUS
82 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for WP15AY36AJ2N. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 82 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 82 / 82 |
| EER2 · BTU/Wh | 11.7–12 | 82 / 82 |
| HSPF2 · BTU/Wh | 7.8 | 82 / 82 |
| Cooling capacity · BTU/h | 34,200 | 82 / 82 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,200–34,200 | 82 / 82 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 22,600–33,200 | 82 / 82 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,300–18,900 | 82 / 82 |
| COP at 5°F / −15°C | 2–2.1 | 82 / 82 |
| Equipment / loop type | HP - Split System | 82 / 82 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 82 / 82 |
| Compressor staging | Two-stage | 82 / 82 |
| Connected capability | No | 82 / 82 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RH2VY3621STACNAHRI reference: 216030724 | 16.00 | 7.80 | 17800 | 2.10 | EPA 3740601 → |
RH2VY3617STACNAHRI reference: 216030727 | 16.00 | 7.80 | 17900 | 2.10 | EPA 3740604 → |
RB2TY3621STANMAHRI reference: 216533395 | 16.00 | 7.80 | 18000 | 2.10 | EPA 3847749 → |
RF2TY3624STANSAHRI reference: 216533482 | 16.00 | 7.80 | 18100 | 2.10 | EPA 3847762 → |
RH2TY3621STANNAHRI reference: 216581255 | 16.00 | 7.80 | 17700 | 2.10 | EPA 3849047 → |
RH2TY3617STANNAHRI reference: 215415477 | 15.20 | 7.80 | 17300 | 2.00 | EPA 3624802 → |
RCFY3617STANM+ furnace: R801V0754A17DZAHRI reference: 215656607 | 15.20 | 7.80 | 18600 | 2.00 | EPA 3644816 → |
RCFY3621STANM+ furnace: R801V1005A21DZAHRI reference: 215656612 | 15.20 | 7.80 | 18200 | 2.00 | EPA 3644821 → |
RCFY3621STANM+ furnace: R801V1005A21UHSAHRI reference: 215656621 | 15.20 | 7.80 | 18300 | 2.00 | EPA 3644830 → |
RCFY3617STANM+ furnace: R801V0503A14DZAHRI reference: 215656631 | 15.20 | 7.80 | 18400 | 2.00 | EPA 3644840 → |
RCFY3617STANM+ furnace: R801V0754A17UHAHRI reference: 215656637 | 15.20 | 7.80 | 18300 | 2.00 | EPA 3644846 → |
RCFY3621STANM+ furnace: R801V0754A17UHAHRI reference: 215656646 | 15.20 | 7.80 | 18300 | 2.00 | EPA 3644855 → |
RCFY3621STANM+ furnace: R801V0755A21UHAHRI reference: 215656648 | 15.20 | 7.80 | 18400 | 2.00 | EPA 3644857 → |
RCFY3617STANM+ furnace: R801V1004A17UHAHRI reference: 215656651 | 15.20 | 7.80 | 18400 | 2.00 | EPA 3644860 → |
RCFY3621STANM+ furnace: R801V1005A21UHNAHRI reference: 215656652 | 15.20 | 7.80 | 18300 | 2.00 | EPA 3644861 → |
RCFY3617STANM+ furnace: R801V0704A17UHAHRI reference: 215656662 | 15.20 | 7.80 | 18700 | 2.00 | EPA 3644871 → |
RCFY3621STANM+ furnace: R801V1004A17UHAHRI reference: 215656664 | 15.20 | 7.80 | 18400 | 2.00 | EPA 3644873 → |
RCFY3621STANM+ furnace: R801V0754A17DZAHRI reference: 215656677 | 15.20 | 7.80 | 18600 | 2.00 | EPA 3644941 → |
RCFY3617STANM+ furnace: R801V0504A17UHSAHRI reference: 215656683 | 15.20 | 7.80 | 18900 | 2.00 | EPA 3644947 → |
RCFY3621STANM+ furnace: R801V0704A17UHAHRI reference: 215656687 | 15.20 | 7.80 | 18700 | 2.00 | EPA 3644951 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →