Heating performance & equipment details
Ranges include the 49 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–17 | 49 / 49 |
| EER2 · BTU/Wh | 9.8–10.5 | 49 / 49 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 49 / 49 |
| Cooling capacity · BTU/h | 56,000–57,000 | 49 / 49 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,000–57,000 | 49 / 49 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 49,000–50,000 | 49 / 49 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,500–45,500 | 49 / 49 |
| COP at 5°F / −15°C | 2 | 49 / 49 |
| Equipment / loop type | HP - Split System | 49 / 49 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 49 / 49 |
| Compressor staging | Continuously variable | 49 / 49 |
| Connected capability | Yes | 49 / 49 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFY6024STANM+ furnace: R962V0705A21M4SCold climate designationAHRI reference: 218327873 | 16.00 | 8.50 | 45500 | 2.00 | EPA 4620698 → |
RCFY6024STANM+ furnace: R951V1155A24M4SCold climate designationAHRI reference: 218327872 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620699 → |
RCFY6024STANM+ furnace: R951V1005A21UHUCold climate designationAHRI reference: 218327871 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620700 → |
RCFY6024STANM+ furnace: R951V1005A21M4UCold climate designationAHRI reference: 218327870 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620701 → |
RCFY6024STANM+ furnace: R951V1005A21M4SCold climate designationAHRI reference: 218327869 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620702 → |
RCFY6024STANM+ furnace: R951V0855A21M4SCold climate designationAHRI reference: 218327868 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620703 → |
RCFY6024STANM+ furnace: R951V0705A21UHUCold climate designationAHRI reference: 218327867 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620704 → |
RCFY6024STANM+ furnace: R951V0705A21M4UCold climate designationAHRI reference: 218327866 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620705 → |
RCFY6024STANM+ furnace: R951V0705A21M4SCold climate designationAHRI reference: 218327865 | 16.00 | 8.50 | 45500 | 2.00 | EPA 4620706 → |
RCFY6024STANM+ furnace: R921V1155A24M4SCold climate designationAHRI reference: 218327864 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620707 → |
RCFY6024STANM+ furnace: R921V1005A21M4SCold climate designationAHRI reference: 218327863 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620708 → |
RCFY6024STANM+ furnace: R921V0855A21M4SCold climate designationAHRI reference: 218327862 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620709 → |
RCFY6024STANM+ furnace: R921V0705A21M4SCold climate designationAHRI reference: 218327861 | 16.00 | 8.50 | 45500 | 2.00 | EPA 4620710 → |
RCFY6024STANM+ furnace: R802V1005A21UHSCold climate designationAHRI reference: 218327854 | 16.00 | 9.50 | 45000 | 2.00 | EPA 4620717 → |
RCFY6024STANM+ furnace: R802V1005A21UHNCold climate designationAHRI reference: 218327853 | 16.00 | 9.50 | 45000 | 2.00 | EPA 4620718 → |
RCFY6024STANM+ furnace: R802V0755A21UHSCold climate designationAHRI reference: 218327850 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620721 → |
RCFY6024STANM+ furnace: R802V0755A21UHNCold climate designationAHRI reference: 218327849 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620722 → |
RCFY6024STANM+ furnace: R802V0755A21DZSCold climate designationAHRI reference: 218327848 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620723 → |
RCFY6024STANM+ furnace: R802V0755A21DZNCold climate designationAHRI reference: 218327847 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620724 → |
RCFY6024STANM+ furnace: R801V1005A21UHUCold climate designationAHRI reference: 218327840 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620731 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.