Ruud / AIR-SOURCE HEAT PUMP

RP15AY42AJ2N

ACHIEVER PLUS · ACHIEVER SERIES · Achiever Plus · source records, page 4

77 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity40,000BTU/h

Each efficiency range summarizes published EPA records for RP15AY42AJ2N. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 77 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1677 / 77
EER2 · BTU/Wh11.7–1277 / 77
HSPF2 · BTU/Wh7.8–8.177 / 77
Cooling capacity · BTU/h40,00077 / 77
Heating capacity at 47°F / 8.3°C · BTU/h40,00077 / 77
Heating capacity at 17°F / −8.3°C · BTU/h24,600–40,00077 / 77
Heating capacity at 5°F / −15°C · BTU/h18,200–21,00066 / 77
COP at 5°F / −15°C2–2.266 / 77
Equipment / loop typeHP - Split System77 / 77
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)77 / 77
Compressor stagingTwo-stage77 / 77
Connected capabilityNo77 / 77

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
RCFY4824STANM+ furnace: R962V1005A21M4Cold climate designationAHRI reference: 21565645316.008.10191002.00EPA 3645945
RH2VY4824STACNCold climate designationAHRI reference: 21603073116.008.10184002.10EPA 3740608
RH2VY4821STACNCold climate designationAHRI reference: 21603073216.008.10185002.00EPA 3740609
RCFY4824STANM+ furnace: U98MV1005A21UPAHRI reference: 21654395516.007.80EPA 3847965
RCFY4821STANM+ furnace: U97MV1005A21DHAHRI reference: 21654395016.007.80EPA 3847966
RCFY4821STANM+ furnace: U98MV1005A21UPAHRI reference: 21654394816.007.80EPA 3847967
RCFY4824STANM+ furnace: U98MV1155A24UPAHRI reference: 21654403516.007.80EPA 3848082
RCFY4824STANM+ furnace: U97MV1005A21DHAHRI reference: 21654404016.007.80EPA 3848083
RH2TY4824STANNCold climate designationAHRI reference: 21658128116.008.10182002.10EPA 3849058
RCFY4824STANM+ furnace: R972V1155A24UPSAHRI reference: 21872830116.008.10208002.20EPA 4704546
RCFY4824STANM+ furnace: R972V1005A21UPSAHRI reference: 21872829516.008.10210002.20EPA 4704552
RCFY4821STANM+ furnace: R972V1005A21UPSAHRI reference: 21872829316.008.10210002.20EPA 4704554
RCFY4824STANM+ furnace: R972V0855A21UPSAHRI reference: 21872828716.008.10210002.20EPA 4704560
RCFY4821STANM+ furnace: R972V0855A21UPSAHRI reference: 21872828516.008.10210002.20EPA 4704562
RCFY4824STANM+ furnace: R972V0705A21UPSAHRI reference: 21872827916.008.10210002.20EPA 4704568
RCFY4821STANM+ furnace: R972V0705A21UPSAHRI reference: 21872827716.008.10210002.20EPA 4704570
RH2TY4821STANNAHRI reference: 21548701815.207.80EPA 3629170

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →