RP15AY42AJ2N
ACHIEVER PLUS · ACHIEVER SERIES · Achiever Plus
77 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RP15AY42AJ2N. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 77 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 77 / 77 |
| EER2 · BTU/Wh | 11.7–12 | 77 / 77 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 77 / 77 |
| Cooling capacity · BTU/h | 40,000 | 77 / 77 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 40,000 | 77 / 77 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–40,000 | 77 / 77 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,200–21,000 | 66 / 77 |
| COP at 5°F / −15°C | 2–2.2 | 66 / 77 |
| Equipment / loop type | HP - Split System | 77 / 77 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 77 / 77 |
| Compressor staging | Two-stage | 77 / 77 |
| Connected capability | No | 77 / 77 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFY4824STANM+ furnace: R802V1255A24DZCold climate designationAHRI reference: 215655134 | 16.00 | 8.10 | 18700 | 2.00 | EPA 3644889 → |
RCFY4824STANM+ furnace: R801V1255A24DZCold climate designationAHRI reference: 215655140 | 16.00 | 8.10 | 18700 | 2.00 | EPA 3644895 → |
RCFY4824STANM+ furnace: R802V0755A21UHCold climate designationAHRI reference: 215655193 | 16.00 | 8.10 | 18900 | 2.00 | EPA 3645105 → |
RCFY4821STANM+ furnace: R801V0755A21DZCold climate designationAHRI reference: 215655201 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645112 → |
RCFY4821STANM+ furnace: R801V0754A17DZCold climate designationAHRI reference: 215655225 | 16.00 | 8.10 | 19300 | 2.00 | EPA 3645134 → |
RCFY4824STANM+ furnace: R802V1255A24UHCold climate designationAHRI reference: 215655226 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645136 → |
RCFY4821STANM+ furnace: R801V0754A17UHCold climate designationAHRI reference: 215655231 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645140 → |
RCFY4821STANM+ furnace: R801V0755A21UHCold climate designationAHRI reference: 215655240 | 16.00 | 8.10 | 18900 | 2.00 | EPA 3645145 → |
RCFY4821STANM+ furnace: R802V1005A21DZCold climate designationAHRI reference: 215655242 | 16.00 | 8.10 | 18700 | 2.00 | EPA 3645149 → |
RCFY4824STANM+ furnace: R801V1505A24UHCold climate designationAHRI reference: 215655249 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645157 → |
RCFY4821STANM+ furnace: R802V0755A21DZCold climate designationAHRI reference: 215655269 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645175 → |
RCFY4824STANM+ furnace: R801V0755A21UHCold climate designationAHRI reference: 215655277 | 16.00 | 8.10 | 18900 | 2.00 | EPA 3645183 → |
RCFY4821STANM+ furnace: R801V1005A21DZCold climate designationAHRI reference: 215655286 | 16.00 | 8.10 | 18700 | 2.00 | EPA 3645190 → |
RCFY4824STANM+ furnace: R801V1255A24UHCold climate designationAHRI reference: 215655299 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645201 → |
RCFY4824STANM+ furnace: R801V0755A21DZCold climate designationAHRI reference: 215655305 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645205 → |
RCFY4821STANM+ furnace: R801V1005A21UHUCold climate designationAHRI reference: 215655319 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645220 → |
RCFY4821STANM+ furnace: R801V0704A17UHCold climate designationAHRI reference: 215655322 | 16.00 | 8.10 | 19300 | 2.00 | EPA 3645222 → |
RCFY4824STANM+ furnace: R802V1505A24UHCold climate designationAHRI reference: 215655321 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645224 → |
RCFY4824STANM+ furnace: R802V1005A21DZCold climate designationAHRI reference: 215655332 | 16.00 | 8.10 | 18700 | 2.00 | EPA 3645230 → |
RCFY4821STANM+ furnace: R802V0754A17UHCold climate designationAHRI reference: 215655334 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645234 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.