SEER2 range18–19BTU/Wh
HSPF2 range8.5–10BTU/Wh
Cooling capacity45,500BTU/h

Each efficiency range summarizes published EPA records for SP19AY48AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 17 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18–1917 / 17
EER2 · BTU/Wh11.7–1217 / 17
HSPF2 · BTU/Wh8.5–1017 / 17
Cooling capacity · BTU/h45,50017 / 17
Heating capacity at 47°F / 8.3°C · BTU/h45,50017 / 17
Heating capacity at 17°F / −8.3°C · BTU/h42,000–43,00017 / 17
Heating capacity at 5°F / −15°C · BTU/h34,800–42,00017 / 17
COP at 5°F / −15°C2.1–2.217 / 17
Equipment / loop typeHP - Split System17 / 17
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)17 / 17
Compressor stagingContinuously variable17 / 17
Connected capabilityNo · Yes17 / 17

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
SHMVY4821SEACAAHRI reference: 21557640419.0010.00420002.10EPA 3630386
TCFY4821SEAAM+ furnace: S802V1005A21DZAHRI reference: 21605125419.0010.00415002.10EPA 3801947
TCFY4821SEAAM+ furnace: S802V0754A17DZAHRI reference: 21605125519.0010.00420002.10EPA 3801948
TCFY4821SEAAM+ furnace: S802V0755A21DZAHRI reference: 21605125919.0010.00415002.10EPA 3801952
TCFY4821SEAAM+ furnace: S802V1005A21UHAHRI reference: 21605126019.0010.00415002.10EPA 3801953
TCFY4821SEAAM+ furnace: S802V0754A17UHAHRI reference: 21605126219.0010.00420002.10EPA 3801955
TCFY4821SEAAM+ furnace: S802V0755A21UHAHRI reference: 21605126319.0010.00420002.10EPA 3801956
TCFY4821SEAAM+ furnace: S97MV1005A21DHAHRI reference: 21605126819.0010.00420002.10EPA 3801961
TCFY4821SEAAM+ furnace: S98MV0855A21UPAHRI reference: 21605126919.0010.00420002.10EPA 3801963
TCFY4821SEAAM+ furnace: S98MV1005A21UPAHRI reference: 21605127519.0010.00420002.10EPA 3801968
TCFY4821SEAAM+ furnace: S97MV0855A21DHAHRI reference: 21605127619.0010.00420002.10EPA 3801969
TCFY4821SEAAM+ furnace: S962V0855A21M4AHRI reference: 21605127919.0010.00420002.10EPA 3801972
TCFY4821SEAAM+ furnace: S972V0855A21UPSAHRI reference: 21872869619.008.50348002.20EPA 4704647
TCFY4821SEAAM+ furnace: S972V0705A21UPSAHRI reference: 21872869419.008.50348002.20EPA 4704649
TCFY4821SEAAM+ furnace: S962V0705A21M4AHRI reference: 21605126618.0010.00420002.10EPA 3801959
TCFY4821SEAAM+ furnace: S962V1005A21M4AHRI reference: 21605127118.0010.00420002.10EPA 3801964
TCFY4821SEAAM+ furnace: S972V1005A21UPSAHRI reference: 21872869818.008.50350002.20EPA 4704645

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.