RUSSELL / AIR-SOURCE HEAT PUMP

SP15AY42AJ2N

VANTIX · source records, page 4

66 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity40,000BTU/h

Each efficiency range summarizes published EPA records for SP15AY42AJ2N. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 66 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1666 / 66
EER2 · BTU/Wh11.7–1266 / 66
HSPF2 · BTU/Wh7.8–8.166 / 66
Cooling capacity · BTU/h40,00066 / 66
Heating capacity at 47°F / 8.3°C · BTU/h40,00066 / 66
Heating capacity at 17°F / −8.3°C · BTU/h27,000–40,00066 / 66
Heating capacity at 5°F / −15°C · BTU/h18,400–19,30060 / 66
COP at 5°F / −15°C2–2.160 / 66
Equipment / loop typeHP - Split System66 / 66
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)66 / 66
Compressor stagingTwo-stage66 / 66
Connected capabilityNo66 / 66

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
TCFY4821STANM+ furnace: S962V1005A21M4Cold climate designationAHRI reference: 21565643416.008.10191002.00EPA 3645932
TCFY4821STANM+ furnace: S97MV1005A21DHAHRI reference: 21565643616.007.80EPA 3645933
TCFY4824STANM+ furnace: S97MV1005A21DHAHRI reference: 21565644316.007.80EPA 3645938
SH2VY4824STACNCold climate designationAHRI reference: 21603077016.008.10184002.10EPA 3740630
SH2VY4821STACNCold climate designationAHRI reference: 21603077116.008.10185002.00EPA 3740631
SH2CY4821STANNAHRI reference: 21548701915.207.80EPA 3629171

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →