SP15AY36AJ2N
VANTIX
71 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for SP15AY36AJ2N. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 71 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 71 / 71 |
| EER2 · BTU/Wh | 11.7–12 | 71 / 71 |
| HSPF2 · BTU/Wh | 7.8 | 71 / 71 |
| Cooling capacity · BTU/h | 34,200 | 71 / 71 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,200–34,200 | 71 / 71 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 23,400–33,200 | 71 / 71 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,300–18,900 | 71 / 71 |
| COP at 5°F / −15°C | 2–2.1 | 71 / 71 |
| Equipment / loop type | HP - Split System | 71 / 71 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 71 / 71 |
| Compressor staging | Two-stage | 71 / 71 |
| Connected capability | No | 71 / 71 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY3617STANM+ furnace: S801V1004A17UHAHRI reference: 215656656 | 16.00 | 7.80 | 18400 | 2.00 | EPA 3644865 → |
TCFY3617STANM+ furnace: S802V1004A17UHAHRI reference: 215656752 | 16.00 | 7.80 | 18400 | 2.00 | EPA 3645016 → |
SH2VY3621STACNAHRI reference: 216030766 | 16.00 | 7.80 | 17800 | 2.10 | EPA 3740626 → |
SH2VY3617STACNAHRI reference: 216030767 | 16.00 | 7.80 | 17900 | 2.10 | EPA 3740627 → |
TCFY3621STANM+ furnace: S801V1004A17UHAHRI reference: 216545283 | 16.00 | 7.80 | 18400 | 2.00 | EPA 3847626 → |
TCFY3621STANM+ furnace: S801V0755A21UHAHRI reference: 216545286 | 16.00 | 7.80 | 18400 | 2.00 | EPA 3847627 → |
TCFY3621STANM+ furnace: S801V0755A21DZAHRI reference: 216545281 | 16.00 | 7.80 | 18300 | 2.00 | EPA 3847628 → |
TCFY3621STANM+ furnace: S801V1005A21DZAHRI reference: 216545291 | 16.00 | 7.80 | 18200 | 2.00 | EPA 3847629 → |
TCFY3621STANM+ furnace: S801V1005A21UHNAHRI reference: 216545293 | 16.00 | 7.80 | 18300 | 2.00 | EPA 3847630 → |
TCFY3621STANM+ furnace: S801V1005A21UHSAHRI reference: 216545304 | 16.00 | 7.80 | 18300 | 2.00 | EPA 3847635 → |
SB2CY3621STANMAHRI reference: 216533523 | 16.00 | 7.80 | 18000 | 2.10 | EPA 3847729 → |
RF2TY3624STANSAHRI reference: 216533502 | 16.00 | 7.80 | 18100 | 2.10 | EPA 3847765 → |
TCFY3621STANM+ furnace: S802V1004A17UHAHRI reference: 216546421 | 16.00 | 7.80 | 18400 | 2.00 | EPA 3847987 → |
TCFY3621STANM+ furnace: S802V0755A21DZAHRI reference: 216546423 | 16.00 | 7.80 | 18300 | 2.00 | EPA 3847988 → |
TCFY3621STANM+ furnace: S802V0755A21UHAHRI reference: 216546428 | 16.00 | 7.80 | 18400 | 2.00 | EPA 3847990 → |
TCFY3621STANM+ furnace: S802V1005A21DZAHRI reference: 216546447 | 16.00 | 7.80 | 18200 | 2.00 | EPA 3847992 → |
TCFY3621STANM+ furnace: S802V1005A21UHAHRI reference: 216546449 | 16.00 | 7.80 | 18300 | 2.00 | EPA 3847993 → |
TCFY3621STANM+ furnace: S951V0705A21UHUAHRI reference: 216545383 | 16.00 | 7.80 | 18500 | 2.00 | EPA 3848218 → |
TCFY3621STANM+ furnace: S801V1005A21UHUAHRI reference: 216545449 | 16.00 | 7.80 | 18400 | 2.00 | EPA 3848232 → |
SH2CY3617STANNAHRI reference: 215415475 | 15.20 | 7.80 | 17300 | 2.00 | EPA 3624800 → |