RUSSELL / AIR-SOURCE HEAT PUMP

RD18AY48AJVC

VANTIX

116 published source records · source checked Sep 21, 2026

SEER2 range16–19BTU/Wh
HSPF2 range8.1–10BTU/Wh
Cooling capacity40,500–43,500BTU/h

Each efficiency range summarizes published EPA records for RD18AY48AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 116 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–19116 / 116
EER2 · BTU/Wh10–12116 / 116
HSPF2 · BTU/Wh8.1–10116 / 116
Cooling capacity · BTU/h40,500–43,500116 / 116
Heating capacity at 47°F / 8.3°C · BTU/h40,500–48,000116 / 116
Heating capacity at 17°F / −8.3°C · BTU/h35,600–40,500116 / 116
Heating capacity at 5°F / −15°C · BTU/h30,800–38,000116 / 116
COP at 5°F / −15°C2–2.2116 / 116
Equipment / loop typeHP - Split System116 / 116
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)116 / 116
Compressor stagingContinuously variable116 / 116
Connected capabilityYes116 / 116

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
SH2VY4824STACNCold climate designationAHRI reference: 21689227419.0010.00372002.10EPA 4009875 →
SH2CY4824STANNCold climate designationAHRI reference: 21716599219.009.50376002.10EPA 4010299 →
SHMVY6024SEACNCold climate designationAHRI reference: 21716599819.008.50328002.10EPA 4010301 →
RH2VY6024STACNAHRI reference: 21661317418.009.50332002.10EPA 3992384 →
TCFY4821STANM+ furnace: S801V1005A21DZCold climate designationAHRI reference: 21689222818.0010.00374002.10EPA 4009871 →
TCFY4824STANM+ furnace: S801V1005A21DZCold climate designationAHRI reference: 21689222918.0010.00374002.10EPA 4009872 →
TCFY4824STANM+ furnace: S802V1005A21DZCold climate designationAHRI reference: 21689223118.0010.00374002.10EPA 4009873 →
TCFY4821STANM+ furnace: S802V1005A21DZCold climate designationAHRI reference: 21689223018.0010.00374002.10EPA 4009874 →
SH2VY4821STACNCold climate designationAHRI reference: 21689227518.0010.00380002.10EPA 4009876 →
TCFY4824MTANM+ furnace: S801V1005A21UHUCold climate designationAHRI reference: 21689213618.008.50332002.00EPA 4009990 →
TCFY4824MTANM+ furnace: S951V1155A24M4Cold climate designationAHRI reference: 21689213418.008.50332002.10EPA 4009991 →
TCFY4824MTANM+ furnace: S801V1005A21UHNCold climate designationAHRI reference: 21689213318.008.50332002.10EPA 4009992 →
TCFY4824MTANM+ furnace: S801V1005A21UHSCold climate designationAHRI reference: 21689213718.008.50332002.10EPA 4009993 →
TCFY4824MTANM+ furnace: S801V1255A24DZCold climate designationAHRI reference: 21689213518.008.50332002.10EPA 4009994 →
TCFY4824MTANM+ furnace: S802V1005A21DZCold climate designationAHRI reference: 21689213018.008.50330002.10EPA 4009995 →
TCFY4824MTANM+ furnace: S802V0755A21DZCold climate designationAHRI reference: 21689213218.008.50332002.10EPA 4009996 →
TCFY4824MTANM+ furnace: S801V1255A24UHCold climate designationAHRI reference: 21689213118.008.50332002.10EPA 4009997 →
TCFY4824MTANM+ furnace: S801V0755A21DZCold climate designationAHRI reference: 21689214218.008.50332002.10EPA 4009998 →
TCFY4824MTANM+ furnace: S801V1005A21DZCold climate designationAHRI reference: 21689214018.008.50330002.10EPA 4009999 →
TCFY4824MTANM+ furnace: S802V1005A21UHCold climate designationAHRI reference: 21689213818.008.50332002.10EPA 4010002 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →