RD18AY36AJVC
VANTIX · source records, page 8
192 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RD18AY36AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–20 | 192 / 192 |
| EER2 · BTU/Wh | 11.7–13 | 192 / 192 |
| HSPF2 · BTU/Wh | 8.1–10 | 192 / 192 |
| Cooling capacity · BTU/h | 31,000–32,800 | 192 / 192 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,000–36,000 | 192 / 192 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,000–31,000 | 192 / 192 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,600–28,200 | 192 / 192 |
| COP at 5°F / −15°C | 1.9–2.2 | 192 / 192 |
| Equipment / loop type | HP - Split System | 192 / 192 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 192 / 192 |
| Compressor staging | Continuously variable | 192 / 192 |
| Connected capability | Yes | 192 / 192 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY3621STANM+ furnace: S801V0704A17UHCold climate designationAHRI reference: 216892191 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995223 → |
TCFY3617STANM+ furnace: S951V0603A17M4Cold climate designationAHRI reference: 216892190 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995224 → |
TCFY3621STANM+ furnace: S97MV0703A17DHCold climate designationAHRI reference: 216892197 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995230 → |
TCFY3621STANM+ furnace: S921V0403A17M4Cold climate designationAHRI reference: 216892199 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995231 → |
TCFY3617STANM+ furnace: S802V0503A14DZCold climate designationAHRI reference: 216892200 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995232 → |
TCFY3617STANM+ furnace: S97MV0703A17DHCold climate designationAHRI reference: 216892198 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995233 → |
TCFY3621STANM+ furnace: S962V0703A17M4Cold climate designationAHRI reference: 216892201 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995234 → |
TCFY3621STANM+ furnace: S951V0403A17UHCold climate designationAHRI reference: 216892203 | 18.00 | 8.50 | 28000 | 1.90 | EPA 3995235 → |
TCFY3621STANM+ furnace: S801V0504A17UHNCold climate designationAHRI reference: 216892202 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995236 → |
TCFY3621STANM+ furnace: S951V0603A17UHCold climate designationAHRI reference: 216892204 | 18.00 | 8.50 | 28000 | 1.90 | EPA 3995237 → |
TCFY3621STANM+ furnace: S98MV0603A17UPCold climate designationAHRI reference: 216892206 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995239 → |
TCFY3617STANM+ furnace: S951V0403A17M4Cold climate designationAHRI reference: 216892207 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995240 → |
TCFY3621STANM+ furnace: S962V0705A21M4Cold climate designationAHRI reference: 216892210 | 18.00 | 8.50 | 27600 | 1.90 | EPA 3995242 → |
TCFY3621STANM+ furnace: S951V0603A17M4Cold climate designationAHRI reference: 216892212 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995243 → |
TCFY3621STANM+ furnace: S962V1005A21M4Cold climate designationAHRI reference: 216892213 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995245 → |
TCFY3621STANM+ furnace: S801V0504A17UHUCold climate designationAHRI reference: 216892215 | 18.00 | 8.50 | 28000 | 1.90 | EPA 3995246 → |
TCFY3617STANM+ furnace: S98MV0603A17UPCold climate designationAHRI reference: 216892216 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995247 → |
TCFY3617STANM+ furnace: S921V0603A17M4Cold climate designationAHRI reference: 216892217 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995248 → |
TCFY3617STANM+ furnace: S802V0503A14UHCold climate designationAHRI reference: 216892218 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995251 → |
TCFY3621STANM+ furnace: S962V0403A17M4Cold climate designationAHRI reference: 216892222 | 18.00 | 8.50 | 27800 | 1.90 | EPA 3995253 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.