RunTru / AIR-SOURCE HEAT PUMP

A5HP5048A1

A5HP5 · source records, page 3

78 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity43,000–45,500BTU/h

Each efficiency range summarizes published EPA records for A5HP5048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 78 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1678 / 78
EER2 · BTU/Wh11.7–1278 / 78
HSPF2 · BTU/Wh7.8–8.178 / 78
Cooling capacity · BTU/h43,000–45,50078 / 78
Heating capacity at 47°F / 8.3°C · BTU/h41,500–44,50078 / 78
Heating capacity at 17°F / −8.3°C · BTU/h27,600–29,40078 / 78
Heating capacity at 5°F / −15°C · BTU/h21,400–22,60078 / 78
COP at 5°F / −15°C2–2.378 / 78
Equipment / loop typeHP - Split System78 / 78
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)78 / 78
Compressor stagingSingle stage78 / 78
Connected capabilityNo78 / 78

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC007AS3+TSTAT+ furnace: A952V100CU5SAAHRI reference: 21429666415.208.10226002.00EPA 3425021
5TXCD010AS3+TSTAT+ furnace: A801X080CM5TDAHRI reference: 21429666615.207.80214002.10EPA 3425023
5TXCD010AS3+TSTAT+ furnace: A801X080CM5SDAHRI reference: 21429666815.207.80214002.10EPA 3425025
5TXCD010AS3+TSTAT+ furnace: A801X100CM5SDAHRI reference: 21429667015.207.80214002.10EPA 3425027
5TXCD010AS3+TSTAT+ furnace: A801X100CM5TDAHRI reference: 21429667415.207.80214002.10EPA 3425031
5TXCD010AS3+TSTAT+ furnace: A801X120DM5SDAHRI reference: 21429667615.207.80222002.10EPA 3425033
5TXCD010AS3+TSTAT+ furnace: A801X120DM5TDAHRI reference: 21429667815.207.80222002.10EPA 3425035
5TXCD010AS3+TSTAT+ furnace: A951X100CU5SAAHRI reference: 21429668015.208.10220002.00EPA 3425037
5TXCD010AS3+TSTAT+ furnace: A951X120DU5SAAHRI reference: 21429668215.208.10220002.20EPA 3425039
5TXCD010AS3+TSTAT+ furnace: A952V080CU5SAAHRI reference: 21429668415.208.10216002.10EPA 3425041
5TXCD010AS3+TSTAT+ furnace: A952V080CU5SBAHRI reference: 21429668615.208.10218002.10EPA 3425043
5TXCD010AS3+TSTAT+ furnace: A952V100CU5SAAHRI reference: 21429668815.208.10214002.10EPA 3425045
5TXCD010AS3+TSTAT+ furnace: A952V100CU5SBAHRI reference: 21429669015.208.10218002.10EPA 3425047
5PX*C007AS3+TSTAT+ furnace: A801X080CM5SDAHRI reference: 21557554615.207.80226002.10EPA 3651111
5PX*C007AS3+TSTAT+ furnace: A801X080CM5TDAHRI reference: 21557554815.207.80226002.10EPA 3651112
5PX*C007AS3+TSTAT+ furnace: A952V100CU5SBAHRI reference: 21557556815.208.00226002.00EPA 3651115
5PX*C009AS3+TSTAT+ furnace: A801X100CM5SDAHRI reference: 21557558215.207.80222002.10EPA 3651173
5PX*C009AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 21557558415.207.80220002.10EPA 3651175
5PX*C009AS3+TSTAT+ furnace: A951X100CU5SAAHRI reference: 21557558615.207.80220002.10EPA 3651177
5PX*C009AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21557558815.207.80220002.20EPA 3651179

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →