RunTru / AIR-SOURCE HEAT PUMP

A5HP5036A1

A5HP5 · source records, page 4

148 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity32,000–35,200BTU/h

Each efficiency range summarizes published EPA records for A5HP5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 148 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16148 / 148
EER2 · BTU/Wh11.7–12148 / 148
HSPF2 · BTU/Wh7.8–8.5148 / 148
Cooling capacity · BTU/h32,000–35,200148 / 148
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,800148 / 148
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,400148 / 148
Heating capacity at 5°F / −15°C · BTU/h16,700–17,800148 / 148
COP at 5°F / −15°C2.1–2.4148 / 148
Equipment / loop typeHP - Split System148 / 148
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)148 / 148
Compressor stagingSingle stage148 / 148
Connected capabilityNo148 / 148

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB004AS3+TSTAT+ furnace: A801X060BM4SDAHRI reference: 21429639615.207.80175002.20EPA 3424013
5TXCB004AS3+TSTAT+ furnace: A951X080BU4SAAHRI reference: 21429640215.208.10174002.20EPA 3424015
5TXCB004AS3+TSTAT+ furnace: A952V040BU3SAAHRI reference: 21429640415.208.10175002.20EPA 3424017
5TXCB004AS3+TSTAT+ furnace: A952V040BU3SBAHRI reference: 21429640615.208.10175002.20EPA 3424023
5TXCB004AS3+TSTAT+ furnace: A952V060BU4SAAHRI reference: 21429640815.208.10173002.20EPA 3424025
5TXCB004AS3+TSTAT+ furnace: A952V060BU4SBAHRI reference: 21429641015.208.10175002.20EPA 3424027
5TXCB004AS3+TSTAT+ furnace: A952V080BU4SAAHRI reference: 21429641215.208.10172002.20EPA 3424029
5TXCB004AS3+TSTAT+ furnace: A952V080BU4SBAHRI reference: 21429641415.208.10172002.20EPA 3424031
5TXCB004AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21429642015.207.80174002.20EPA 3424033
5TXCB004AS3+TSTAT+ furnace: A951X040BU3SAAHRI reference: 21429642615.208.10176002.20EPA 3424037
5TXCB006AS3+TSTAT+ furnace: A951X060BU4SAAHRI reference: 21429642815.208.10173002.30EPA 3424039
5TXCB006AS3+TSTAT+ furnace: A951X040BU3SAAHRI reference: 21429643015.208.10171002.30EPA 3424042
5TXCB006AS3+TSTAT+ furnace: A801X080BM4TDAHRI reference: 21429643215.208.10174002.30EPA 3424043
5TXCB006AS3+TSTAT+ furnace: A801X080BM4SDAHRI reference: 21429643415.208.10174002.30EPA 3424045
5TXCB006AS3+TSTAT+ furnace: A801X060BM4TDAHRI reference: 21429643615.208.10173002.30EPA 3424047
5TXCB006AS3+TSTAT+ furnace: A801X060BM4SDAHRI reference: 21429643815.208.10173002.30EPA 3424049
5TXCB006AS3+TSTAT+ furnace: A801X040AM3TDAHRI reference: 21429644015.207.80170002.20EPA 3424051
5TXCB006AS3+TSTAT+ furnace: A801X040AM3SDAHRI reference: 21429644215.207.80170002.20EPA 3424053
5TXCB006AS3+TSTAT+ furnace: A951X080BU4SAAHRI reference: 21429644415.208.10173002.30EPA 3424056
5TXCB006AS3+TSTAT+ furnace: L9X1B070U4VSAAHRI reference: 21429645215.207.80177002.20EPA 3424061