RunTru / AIR-SOURCE HEAT PUMP

A5HP5030A1

A5HP5

41 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity26,800–29,000BTU/h

Each efficiency range summarizes published EPA records for A5HP5030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 41 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1641 / 41
EER2 · BTU/Wh11.7–1241 / 41
HSPF2 · BTU/Wh7.8–8.141 / 41
Cooling capacity · BTU/h26,800–29,00041 / 41
Heating capacity at 47°F / 8.3°C · BTU/h24,200–26,40041 / 41
Heating capacity at 17°F / −8.3°C · BTU/h16,300–17,60041 / 41
Heating capacity at 5°F / −15°C · BTU/h12,700–13,70041 / 41
COP at 5°F / −15°C2–2.241 / 41
Equipment / loop typeHP - Split System41 / 41
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)41 / 41
Compressor stagingSingle stage41 / 41
Connected capabilityNo41 / 41

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
A5AHV004A1D3+TDR+TSTATAHRI reference: 21429637216.008.10137002.10EPA 3423666
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21557472616.007.80135002.10EPA 3650663
5PX*B006AS3+TSTAT+ furnace: A801X040AM3TDAHRI reference: 21557473016.008.10127002.00EPA 3650665
5PX*B006AS3+TSTAT+ furnace: A801X040AM3SDAHRI reference: 21557473216.008.10127002.00EPA 3650667
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 21557482216.008.00137002.10EPA 3651125
5PX*C007AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 21557483216.008.00133002.10EPA 3651160
A5AHV005A1D3+TDR+TSTATAHRI reference: 21561108416.008.10137002.10EPA 3651538
5TXCB004AS3+TSTAT+ furnace: A952V060BU4SAAHRI reference: 21429631415.207.80135002.00EPA 3423733
5TXCB004AS3+TSTAT+ furnace: A952V040BU3SBAHRI reference: 21429631615.207.80135002.00EPA 3423736
5TXCB004AS3+TSTAT+ furnace: A952V040BU3SAAHRI reference: 21429631815.207.80134002.00EPA 3423739
5TXCB004AS3+TSTAT+ furnace: A951X080BU4SAAHRI reference: 21429632015.207.80137002.00EPA 3423742
5TXCB004AS3+TSTAT+ furnace: A951X060BU4SAAHRI reference: 21429632215.207.80134002.00EPA 3423746
5TXCB004AS3+TSTAT+ furnace: A951X040BU3SAAHRI reference: 21429632415.207.80135002.00EPA 3423748
5TXCB006AS3+TSTAT+ furnace: A952V080BU4SAAHRI reference: 21429632815.208.10134002.10EPA 3423750
5TXCB006AS3+TSTAT+ furnace: A801X040AM3SDAHRI reference: 21429633015.207.80127002.00EPA 3423752
5TXCB006AS3+TSTAT+ furnace: A801X040AM3TDAHRI reference: 21429633215.208.10127002.00EPA 3423754
5TXCB006AS3+TSTAT+ furnace: A801X060BM4SDAHRI reference: 21429633415.207.80135002.10EPA 3423756
5TXCB006AS3+TSTAT+ furnace: A801X060BM4TDAHRI reference: 21429633615.207.80135002.10EPA 3423759
5TXCB006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21429634615.207.80133002.10EPA 3423765
5TXCB006AS3+TSTAT+ furnace: L8V1A060U3VSBAHRI reference: 21429634815.207.80130002.00EPA 3423767