RunTru / AIR-SOURCE HEAT PUMP

A5HP5024A1

A5HP5 · source records, page 2

36 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity21,200–24,400BTU/h

Each efficiency range summarizes published EPA records for A5HP5024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 36 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1636 / 36
EER2 · BTU/Wh11.7–1236 / 36
HSPF2 · BTU/Wh7.8–8.136 / 36
Cooling capacity · BTU/h21,200–24,40036 / 36
Heating capacity at 47°F / 8.3°C · BTU/h20,600–23,00036 / 36
Heating capacity at 17°F / −8.3°C · BTU/h13,700–15,30036 / 36
Heating capacity at 5°F / −15°C · BTU/h10,600–11,80036 / 36
COP at 5°F / −15°C1.9–2.136 / 36
Equipment / loop typeHP - Split System36 / 36
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)36 / 36
Compressor stagingSingle stage36 / 36
Connected capabilityNo36 / 36

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB004AS3+TSTAT+ furnace: L8V1A040U3VSBAHRI reference: 21429621215.207.80110002.00EPA 3423638
5TXCB004AS3+TSTAT+ furnace: L8V1A060U3VSBAHRI reference: 21429621415.207.80111002.00EPA 3423640
5TXCB004AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21429621615.207.80114002.00EPA 3423642
5TXCB004AS3+TSTAT+ furnace: L9X1A050U3VSAAHRI reference: 21429621815.207.80106001.90EPA 3423644
5TXCB004AS3+TSTAT+ furnace: A801X080BM4SDAHRI reference: 21429622615.207.80113002.00EPA 3423648
5TXCB004AS3+TSTAT+ furnace: A801X060BM4TDAHRI reference: 21429622815.207.80113002.00EPA 3423650
5TXCB004AS3+TSTAT+ furnace: A801X060BM4SDAHRI reference: 21429623015.207.80113002.00EPA 3423652
5TXCB004AS3+TSTAT+ furnace: A801X040BM2TDAHRI reference: 21429623215.207.80112002.00EPA 3423654
5TXCB004AS3+TSTAT+ furnace: A801X040BM2SDAHRI reference: 21429623415.207.80112002.00EPA 3424568
5TXCB004AS3+TSTAT+ furnace: A801X040AM3TDAHRI reference: 21429623615.207.80109002.00EPA 3424570
5TXCB004AS3+TSTAT+ furnace: A801X040AM3SDAHRI reference: 21429623815.207.80109002.00EPA 3424572
A5AHV003A1B3+TDR+TSTATAHRI reference: 21429626415.208.10118002.10EPA 3424697
A5AHC002A1B3+TDR+TSTATAHRI reference: 21561106415.207.80112002.10EPA 3651520
A5AHC003A1B3+TDR+TSTATAHRI reference: 21561106615.208.10114002.10EPA 3651522
A5AHC004A1D3+TDR+TSTATAHRI reference: 21561106815.208.10111002.10EPA 3651524
A5AHV002A1B3+TDR+TSTATAHRI reference: 21561107015.208.10113002.10EPA 3651526

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →