ROYALTON / AIR-SOURCE HEAT PUMP

4HP17L36P-**A

4HP17 SERIES · 4HP17 Series · 4HP17L SERIES · 4HP17L Series · source records, page 6

141 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.6BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 141 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.6141 / 141
EER2 · BTU/Wh12.2–13.5141 / 141
HSPF2 · BTU/Wh7.8–8.7141 / 141
Cooling capacity · BTU/h34,800–36,000141 / 141
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000141 / 141
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800141 / 141
Heating capacity at 5°F / −15°C · BTU/h16,800–19,100141 / 141
COP at 5°F / −15°C2.08–2.36141 / 141
Equipment / loop typeHP - Split System141 / 141
Refrigerant / source-reported GWPR-410A (GWP:2088)141 / 141
Compressor stagingSingle stage141 / 141
Connected capabilityNo141 / 141

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X50/60C+TDR+ furnace: 80G1UH100CE20XAHRI reference: 21032702715.807.80176002.12EPA 2458153
EA(C;U)1P36A+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21032692015.807.80174002.10EPA 2458453
EAC4X36B+TDR+ furnace: 92G1UH045BE12AHRI reference: 21032700615.807.80170002.08EPA 2458463
EAC4X36A+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21032699915.807.80170002.08EPA 2458470
EAC4X50/60C+TDR+ furnace: 80G2UH110CV20AHRI reference: 21032703615.807.80174002.10EPA 2458767
EA(C;U)1P36B+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21032693115.807.80173002.10EPA 2458917
EAC4X36A+TDR+ furnace: 80G2UH070AV12AHRI reference: 21032700115.807.80174002.10EPA 2459154
EAC4X36B+TDR+ furnace: 96G1UH030BE08AHRI reference: 21032701315.807.80173002.10EPA 2459247
EAC4X50/60C+TDR+ furnace: 95G1UH080CE16XAHRI reference: 21032703315.807.80172002.10EPA 2459296
EA(C;U)1P36B+TDR+TXV+ furnace: 95G1UH040BE12XAHRI reference: 21032693315.807.80170002.12EPA 2459313
BCE5V36M*4XAHRI reference: 21032691115.808.10174002.20EPA 2461176
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21032691815.807.80170002.08EPA 2461419
EAH1P48B*+TDR+TXV+ furnace: 80G1UH080BE16XAHRI reference: 21173626715.807.80172002.18EPA 2466205
EAH1P48B*+TDR+TXV+ furnace: 95G1UH060BE12XAHRI reference: 21173629115.807.80172002.18EPA 2466653
EAH1P48B*+TDR+TXV+ furnace: 80G2UH090BV16AHRI reference: 21173651415.808.00176002.22EPA 2469301
EAD4X-30/36B+TDR+ furnace: 80G1DF090BE16AHRI reference: 21326537615.808.00187002.14EPA 2839888
EAD4X-30/36C+TDR+ furnace: 96G1DF110CE20AHRI reference: 21326538615.808.10189002.12EPA 2839963
EAD4X-30/36C+TDR+ furnace: 92G1DF090CE16AHRI reference: 21326538415.808.00187002.14EPA 2839983
7ED48CX-0*+TDR+ furnace: 97G2DF110CV20AHRI reference: 21483166015.808.60190002.26EPA 3544428
7EC50/60CX-0*+TDR+ furnace: 97G2UH090CV20AHRI reference: 21483165415.807.80176002.12EPA 3544454

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →