ROYALTON / AIR-SOURCE HEAT PUMP

4HP17L36P-**A

4HP17 SERIES · 4HP17 Series · 4HP17L SERIES · 4HP17L Series · source records, page 3

141 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.6BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 141 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.6141 / 141
EER2 · BTU/Wh12.2–13.5141 / 141
HSPF2 · BTU/Wh7.8–8.7141 / 141
Cooling capacity · BTU/h34,800–36,000141 / 141
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000141 / 141
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800141 / 141
Heating capacity at 5°F / −15°C · BTU/h16,800–19,100141 / 141
COP at 5°F / −15°C2.08–2.36141 / 141
Equipment / loop typeHP - Split System141 / 141
Refrigerant / source-reported GWPR-410A (GWP:2088)141 / 141
Compressor stagingSingle stage141 / 141
Connected capabilityNo141 / 141

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAH1P48B*+TDR+TXV+ furnace: 80G2UH090BE16LAHRI reference: 21173633216.208.00172002.20EPA 2463255 →
EAH1P48B*+TDR+TXV+ furnace: 80G2UH090BE16AHRI reference: 21173631816.208.00172002.20EPA 2463711 →
EAH1P48B*+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 21173641616.208.00172002.24EPA 2464487 →
EAH1P51C*+TDR+TXV+ furnace: 92G1UH090CE16AHRI reference: 21173673516.207.80173002.16EPA 2464909 →
EAH1P51C*+TDR+TXV+ furnace: 96G1UH090CE16AHRI reference: 21173678216.208.00175002.18EPA 2465346 →
EAH1P48B*+TDR+TXV+ furnace: 80G2UH090BE12AHRI reference: 21173630216.208.00174002.22EPA 2467962 →
EAH1P51C*+TDR+TXV+ furnace: 92G1UH090CE12AHRI reference: 21173672016.207.80175002.16EPA 2469290 →
EAD4X-48C+TDR+ furnace: 96G1DF090CE16AHRI reference: 21326539316.208.70191002.34EPA 2839880 →
EAD4X-48C+TDR+ furnace: 92G1DF090CE16AHRI reference: 21326539216.208.70191002.32EPA 2839881 →
EAD4X-48C+TDR+ furnace: 96G1DF110CE20AHRI reference: 21326539416.208.70189002.34EPA 2839924 →
EAD4X-30/36C+TDR+ furnace: 80G1DF110CE20AHRI reference: 21326538316.208.10184002.16EPA 2839982 →
7EH42CX-0*+TDR+ furnace: 97G2UH110CV20AHRI reference: 21483166516.208.10182002.20EPA 3544432 →
7EH51CX-0*+TDR+ furnace: 97G2UH090CV12AHRI reference: 21483166816.208.00176002.18EPA 3544434 →
7EH51CX-0*+TDR+ furnace: 97G2UH110CV20AHRI reference: 21483167016.208.10176002.18EPA 3544435 →
7EH42CX-0*+TDR+ furnace: 97G2UH090CV12AHRI reference: 21483166316.208.00182002.22EPA 3544470 →
EA(C;U)1P50/60C+TDR+TXV+ furnace: 95G1UH100CE20XAHRI reference: 21032694416.007.80172002.12EPA 2455838 →
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH045AE12AHRI reference: 21032691416.007.80170002.12EPA 2455850 →
EA(C;U)1P36B+TDR+TXV+ furnace: 95G1UH060BE12XAHRI reference: 21032692616.007.80171002.12EPA 2455969 →
EA(C;U)1P36A+TDR+TXV+ furnace: 80G2UH045AE12AHRI reference: 21032691916.007.80174002.14EPA 2455973 →
EAC4X50/60C+TDR+ furnace: 92G1UH110CE20AHRI reference: 21032702616.007.80172002.12EPA 2456003 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →