Rheem / AIR-SOURCE HEAT PUMP

WP15AY36AJ2N

CLASSIC PLUS · VERSUS · source records, page 4

81 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity34,200BTU/h

Each efficiency range summarizes published EPA records for WP15AY36AJ2N. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 81 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1681 / 81
EER2 · BTU/Wh11.7–1281 / 81
HSPF2 · BTU/Wh7.881 / 81
Cooling capacity · BTU/h34,20081 / 81
Heating capacity at 47°F / 8.3°C · BTU/h33,200–34,20081 / 81
Heating capacity at 17°F / −8.3°C · BTU/h22,600–33,20081 / 81
Heating capacity at 5°F / −15°C · BTU/h17,300–18,90081 / 81
COP at 5°F / −15°C2–2.181 / 81
Equipment / loop typeHP - Split System81 / 81
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)81 / 81
Compressor stagingTwo-stage81 / 81
Connected capabilityNo81 / 81

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
RCFY3621STANM+ furnace: R962V1005A21M4AHRI reference: 21565712715.207.80185002.00EPA 3645592
RCFY3617STANM+ furnace: R962V0603A17M4AHRI reference: 21565717115.207.80186002.00EPA 3645600
RCFY3621STANM+ furnace: R962V0855A21M4AHRI reference: 21565720815.207.80186002.00EPA 3645607
RCFY3621STANM+ furnace: R97MV0855A21DHAHRI reference: 21565724815.207.80181002.00EPA 3645617
RCFY3621STANM+ furnace: R962V0603A17M4AHRI reference: 21565725015.207.80186002.00EPA 3645618
RCFY3621STANM+ furnace: R962V0403A17M4AHRI reference: 21565726915.207.80186002.00EPA 3645623
RCFY3621STANM+ furnace: R962V0703A17M4AHRI reference: 21565727815.207.80184002.00EPA 3645691
RCFY3617STANM+ furnace: R962V0403A17M4AHRI reference: 21565730815.207.80186002.00EPA 3645695
RCFY3617STANM+ furnace: R802V0504A17UHAHRI reference: 21565743015.207.80189002.00EPA 3645767
RCFY3621STANM+ furnace: R801V0504A17UHUAHRI reference: 21565746415.207.80187002.00EPA 3645799
RCFY3621STANM+ furnace: R801V1005A21UHUAHRI reference: 21565746915.207.80184002.00EPA 3645804
RCFY3621STANM+ furnace: R972V1005A21UPSAHRI reference: 21872825415.207.80187002.00EPA 4704593
RCFY3621STANM+ furnace: R972V0855A21UPSAHRI reference: 21872825015.207.80188002.00EPA 4704597
RCFY3621STANM+ furnace: R972V0705A21UPSAHRI reference: 21872824615.207.80188002.00EPA 4704601
RCFY3621STANM+ furnace: R972V0703A17UPSAHRI reference: 21872824215.207.80186002.00EPA 4704605
RCFY3617STANM+ furnace: R972V0703A17UPSAHRI reference: 21872824015.207.80186002.00EPA 4704607
RCFY3621STANM+ furnace: R972V0603A17UPSAHRI reference: 21872823415.207.80189002.00EPA 4704613
RCFY3617STANM+ furnace: R972V0603A17UPSAHRI reference: 21872823215.207.80189002.00EPA 4704615
RCFY3621STANM+ furnace: R972V0403A17UPSAHRI reference: 21872822615.207.80188002.00EPA 4704621
RCFY3617STANM+ furnace: R972V0403A17UPSAHRI reference: 21872822415.207.80188002.00EPA 4704623

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →