RP19AY48AJVC
PRESTIGE SERIES
26 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RP19AY48AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 26 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–19 | 26 / 26 |
| EER2 · BTU/Wh | 11.7–12 | 26 / 26 |
| HSPF2 · BTU/Wh | 8.5–10 | 26 / 26 |
| Cooling capacity · BTU/h | 45,500 | 26 / 26 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,500 | 26 / 26 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 42,000–43,000 | 26 / 26 |
| Heating capacity at 5°F / −15°C · BTU/h | 34,800–42,000 | 26 / 26 |
| COP at 5°F / −15°C | 2.1–2.2 | 26 / 26 |
| Equipment / loop type | HP - Split System | 26 / 26 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 26 / 26 |
| Compressor staging | Continuously variable | 26 / 26 |
| Connected capability | No · Yes | 26 / 26 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RHMVY4821SEACAAHRI reference: 215576396 | 19.00 | 10.00 | 42000 | 2.10 | EPA 3630380 → |
RCFY4821SEAAM+ furnace: R802V0754A17UHAHRI reference: 216051117 | 19.00 | 10.00 | 42000 | 2.10 | EPA 3801876 → |
RCFY4821SEAAM+ furnace: R802V0755A21DZAHRI reference: 216051120 | 19.00 | 10.00 | 41500 | 2.10 | EPA 3801878 → |
RCFY4821SEAAM+ furnace: R802V1005A21DZAHRI reference: 216051121 | 19.00 | 10.00 | 41500 | 2.10 | EPA 3801879 → |
RCFY4821SEAAM+ furnace: R802V1005A21UHAHRI reference: 216051122 | 19.00 | 10.00 | 41500 | 2.10 | EPA 3801880 → |
RCFY4821SEAAM+ furnace: R802V0754A17DZAHRI reference: 216051123 | 19.00 | 10.00 | 42000 | 2.10 | EPA 3801881 → |
RCFY4821SEAAM+ furnace: R802V0755A21UHAHRI reference: 216051124 | 19.00 | 10.00 | 42000 | 2.10 | EPA 3801882 → |
RCFY4821SEAAM+ furnace: R97MV1005A21DHAHRI reference: 216051131 | 19.00 | 10.00 | 42000 | 2.10 | EPA 3801889 → |
RCFY4821SEAAM+ furnace: R98MV0855A21UPAHRI reference: 216051132 | 19.00 | 10.00 | 42000 | 2.10 | EPA 3801890 → |
RCFY4821SEAAM+ furnace: R962V0855A21M4AHRI reference: 216051133 | 19.00 | 10.00 | 42000 | 2.10 | EPA 3801891 → |
RCFY4821SEAAM+ furnace: R98MV1005A21UPAHRI reference: 216051138 | 19.00 | 10.00 | 42000 | 2.10 | EPA 3801896 → |
RCFY4821SEAAM+ furnace: R97MV0855A21DHAHRI reference: 216051139 | 19.00 | 10.00 | 42000 | 2.10 | EPA 3801897 → |
RCFY4821SEAAM+ furnace: R802V1004A17UHAHRI reference: 217733378 | 19.00 | 8.50 | 42000 | 2.10 | EPA 4498795 → |
RCFY4821SEAAM+ furnace: R921V0855A21M4AHRI reference: 217733380 | 19.00 | 8.50 | 42000 | 2.10 | EPA 4498797 → |
RCFY4821SEAAM+ furnace: R951V0705A21M4UAHRI reference: 217733383 | 19.00 | 8.50 | 42000 | 2.10 | EPA 4498800 → |
RCFY4821SEAAM+ furnace: R951V0855A21M4SAHRI reference: 217733384 | 19.00 | 8.50 | 42000 | 2.10 | EPA 4498801 → |
RCFY4821SEAAM+ furnace: R951V1005A21M4UAHRI reference: 217733386 | 19.00 | 8.50 | 42000 | 2.10 | EPA 4498803 → |
RCFY4821SEAAM+ furnace: R972V0855A21UPSAHRI reference: 218728690 | 19.00 | 8.50 | 34800 | 2.20 | EPA 4704653 → |
RCFY4821SEAAM+ furnace: R972V0705A21UPSAHRI reference: 218728688 | 19.00 | 8.50 | 34800 | 2.20 | EPA 4704655 → |
RCFY4821SEAAM+ furnace: R962V0705A21M4AHRI reference: 216051129 | 18.00 | 10.00 | 42000 | 2.10 | EPA 3801887 → |