RP17AY60AJVC
Classic Plus · source records, page 2
49 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RP17AY60AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 49 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–17 | 49 / 49 |
| EER2 · BTU/Wh | 9.8–10.5 | 49 / 49 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 49 / 49 |
| Cooling capacity · BTU/h | 56,000–57,000 | 49 / 49 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,000–57,000 | 49 / 49 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 49,000–50,000 | 49 / 49 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,500–45,500 | 49 / 49 |
| COP at 5°F / −15°C | 2 | 49 / 49 |
| Equipment / loop type | HP - Split System | 49 / 49 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 49 / 49 |
| Compressor staging | Continuously variable | 49 / 49 |
| Connected capability | Yes | 49 / 49 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFY6024STANM+ furnace: R962V0705A21M4SCold climate designationAHRI reference: 218160590 | 16.00 | 8.50 | 45500 | 2.00 | EPA 4620167 → |
RCFY6024STANM+ furnace: R951V1155A24M4SCold climate designationAHRI reference: 218160589 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620168 → |
RCFY6024STANM+ furnace: R951V1005A21UHUCold climate designationAHRI reference: 218160588 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620169 → |
RCFY6024STANM+ furnace: R951V1005A21M4UCold climate designationAHRI reference: 218160587 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620170 → |
RCFY6024STANM+ furnace: R951V1005A21M4SCold climate designationAHRI reference: 218160586 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620171 → |
RCFY6024STANM+ furnace: R951V0855A21M4SCold climate designationAHRI reference: 218160585 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620172 → |
RCFY6024STANM+ furnace: R951V0705A21UHUCold climate designationAHRI reference: 218160584 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620173 → |
RCFY6024STANM+ furnace: R951V0705A21M4UCold climate designationAHRI reference: 218160583 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620174 → |
RCFY6024STANM+ furnace: R951V0705A21M4SCold climate designationAHRI reference: 218160582 | 16.00 | 8.50 | 45500 | 2.00 | EPA 4620175 → |
RCFY6024STANM+ furnace: R921V1155A24M4SCold climate designationAHRI reference: 218160581 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620176 → |
RCFY6024STANM+ furnace: R921V1005A21M4SCold climate designationAHRI reference: 218160580 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620177 → |
RCFY6024STANM+ furnace: R921V0855A21M4SCold climate designationAHRI reference: 218160579 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620178 → |
RCFY6024STANM+ furnace: R921V0705A21M4SCold climate designationAHRI reference: 218160578 | 16.00 | 8.50 | 45500 | 2.00 | EPA 4620179 → |
RCFY6024STANM+ furnace: R802V1005A21UHSCold climate designationAHRI reference: 218160571 | 16.00 | 9.50 | 45000 | 2.00 | EPA 4620186 → |
RCFY6024STANM+ furnace: R802V1005A21UHNCold climate designationAHRI reference: 218160570 | 16.00 | 9.50 | 45000 | 2.00 | EPA 4620187 → |
RCFY6024STANM+ furnace: R802V0755A21UHSCold climate designationAHRI reference: 218160567 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620190 → |
RCFY6024STANM+ furnace: R802V0755A21UHNCold climate designationAHRI reference: 218160566 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620191 → |
RCFY6024STANM+ furnace: R802V0755A21DZSCold climate designationAHRI reference: 218160565 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620192 → |
RCFY6024STANM+ furnace: R802V0755A21DZNCold climate designationAHRI reference: 218160564 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620193 → |
RCFY6024STANM+ furnace: R801V1005A21UHUCold climate designationAHRI reference: 218160557 | 16.00 | 9.50 | 45500 | 2.00 | EPA 4620200 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →