Rheem / AIR-SOURCE HEAT PUMP

RP17AY48AJVC

Classic Plus · source records, page 2

111 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity44,000–45,500BTU/h

Each efficiency range summarizes published EPA records for RP17AY48AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 111 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16111 / 111
EER2 · BTU/Wh9–11111 / 111
HSPF2 · BTU/Wh8.5–9.5111 / 111
Cooling capacity · BTU/h44,000–45,500111 / 111
Heating capacity at 47°F / 8.3°C · BTU/h44,000–45,500111 / 111
Heating capacity at 17°F / −8.3°C · BTU/h39,000–40,000111 / 111
Heating capacity at 5°F / −15°C · BTU/h33,200–37,600111 / 111
COP at 5°F / −15°C2–2.1111 / 111
Equipment / loop typeHP - Split System111 / 111
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)111 / 111
Compressor stagingContinuously variable111 / 111
Connected capabilityYes111 / 111

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
RCFY4824STANM+ furnace: R921V0705A21M4SCold climate designationAHRI reference: 21816052816.009.50370002.00EPA 4621145 →
RCFY4821STANM+ furnace: R921V0705A21M4SCold climate designationAHRI reference: 21816052716.009.50370002.00EPA 4621146 →
RCFY4824STANM+ furnace: R98MV1155A24UPSCold climate designationAHRI reference: 21816052616.009.50370002.00EPA 4621147 →
RCFY4824STANM+ furnace: R98MV1005A21UPSCold climate designationAHRI reference: 21816052516.009.50372002.00EPA 4621148 →
RCFY4821STANM+ furnace: R98MV1005A21UPSCold climate designationAHRI reference: 21816052416.009.50372002.00EPA 4621149 →
RCFY4824STANM+ furnace: R98MV0855A21UPSCold climate designationAHRI reference: 21816052316.009.50370002.00EPA 4621150 →
RCFY4821STANM+ furnace: R98MV0855A21UPSCold climate designationAHRI reference: 21816052216.009.50370002.00EPA 4621151 →
RCFY4824STANM+ furnace: R97MV1155A24DHSCold climate designationAHRI reference: 21816052116.009.50370002.00EPA 4621152 →
RCFY4824STANM+ furnace: R97MV1005A21DHSCold climate designationAHRI reference: 21816052016.009.50368002.00EPA 4621153 →
RCFY4821STANM+ furnace: R97MV1005A21DHSCold climate designationAHRI reference: 21816051916.009.50368002.00EPA 4621154 →
RCFY4824STANM+ furnace: R97MV0855A21DHSCold climate designationAHRI reference: 21816051816.009.50370002.00EPA 4621155 →
RCFY4821STANM+ furnace: R97MV0855A21DHSCold climate designationAHRI reference: 21816051716.009.50370002.00EPA 4621156 →
RCFY4824STANM+ furnace: R962V1155A24M4SCold climate designationAHRI reference: 21816051616.009.50368002.00EPA 4621157 →
RCFY4824STANM+ furnace: R962V1005A21M4SCold climate designationAHRI reference: 21816051516.009.50370002.00EPA 4621158 →
RCFY4821STANM+ furnace: R962V1005A21M4SCold climate designationAHRI reference: 21816051416.009.50370002.00EPA 4621159 →
RCFY4824STANM+ furnace: R962V0855A21M4SCold climate designationAHRI reference: 21816051316.009.50370002.00EPA 4621160 →
RCFY4821STANM+ furnace: R962V0855A21M4SCold climate designationAHRI reference: 21816051216.009.50370002.00EPA 4621161 →
RCFY4824STANM+ furnace: R962V0705A21M4SCold climate designationAHRI reference: 21816051116.009.50370002.00EPA 4621162 →
RCFY4821STANM+ furnace: R962V0705A21M4SCold climate designationAHRI reference: 21816051016.009.50370002.00EPA 4621163 →
RCFY4824STANM+ furnace: R802V1505A24UHSCold climate designationAHRI reference: 21816050916.009.50366002.00EPA 4621164 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →