RD18AY48AJVC
PRESTIGE SERIES · source records, page 5
112 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RD18AY48AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 112 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19 | 112 / 112 |
| EER2 · BTU/Wh | 10–12 | 112 / 112 |
| HSPF2 · BTU/Wh | 8.1–10 | 112 / 112 |
| Cooling capacity · BTU/h | 40,500–43,500 | 112 / 112 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 40,500–43,000 | 112 / 112 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 35,600–40,500 | 112 / 112 |
| Heating capacity at 5°F / −15°C · BTU/h | 30,800–38,000 | 112 / 112 |
| COP at 5°F / −15°C | 2–2.2 | 112 / 112 |
| Equipment / loop type | HP - Split System | 112 / 112 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 112 / 112 |
| Compressor staging | Continuously variable | 112 / 112 |
| Connected capability | Yes | 112 / 112 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFY4821STANM+ furnace: R962V1005A21M4Cold climate designationAHRI reference: 216819887 | 17.00 | 10.00 | 37800 | 2.10 | EPA 4028066 → |
RCFY4821STANM+ furnace: R921V0705A21M4Cold climate designationAHRI reference: 216819921 | 17.00 | 10.00 | 37800 | 2.10 | EPA 4028072 → |
RCFY4821STANM+ furnace: R98MV0855A21UPCold climate designationAHRI reference: 216819926 | 17.00 | 10.00 | 37800 | 2.10 | EPA 4028074 → |
RCFY4821STANM+ furnace: R962V0855A21M4Cold climate designationAHRI reference: 216819931 | 17.00 | 10.00 | 37800 | 2.10 | EPA 4028076 → |
RCFY4824STANM+ furnace: R962V1005A21M4Cold climate designationAHRI reference: 216819955 | 17.00 | 10.00 | 37800 | 2.10 | EPA 4028081 → |
RCFY4824STANM+ furnace: R921V0705A21M4Cold climate designationAHRI reference: 216819971 | 17.00 | 10.00 | 37800 | 2.10 | EPA 4028086 → |
RCFY4821STANM+ furnace: R802V1004A17UHCold climate designationAHRI reference: 216820147 | 17.00 | 8.10 | 37800 | 2.10 | EPA 4028124 → |
RCFY4821STANM+ furnace: R921V0855A21M4Cold climate designationAHRI reference: 216820003 | 17.00 | 10.00 | 37800 | 2.10 | EPA 4028138 → |
RCFY4821STANM+ furnace: R951V0855A21M4Cold climate designationAHRI reference: 216820018 | 17.00 | 10.00 | 37800 | 2.10 | EPA 4028141 → |
RCFY4821STANM+ furnace: R951V1005A21M4Cold climate designationAHRI reference: 216820024 | 17.00 | 10.00 | 37800 | 2.10 | EPA 4028143 → |
RCFY4824STANM+ furnace: R951V1005A21M4Cold climate designationAHRI reference: 216820041 | 17.00 | 10.00 | 37800 | 2.10 | EPA 4028149 → |
RCFY4824MTANM+ furnace: R962V0705A21M4Cold climate designationAHRI reference: 216819490 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4028151 → |
RCFY4824MTANM+ furnace: R97MV1155A24DHCold climate designationAHRI reference: 216819499 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4028153 → |
RCFY4824MTANM+ furnace: R97MV0855A21DHCold climate designationAHRI reference: 216819524 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4028159 → |
RCFY4824MTANM+ furnace: R921V0855A21M4Cold climate designationAHRI reference: 216819529 | 17.00 | 9.50 | 33600 | 2.00 | EPA 4028161 → |
RCFY4824MTANM+ furnace: R951V0705A21M4Cold climate designationAHRI reference: 216819536 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4028163 → |
RCFY4824STANM+ furnace: R97MV0855A21DHCold climate designationAHRI reference: 216820065 | 17.00 | 10.00 | 37800 | 2.10 | EPA 4028250 → |
RCFY4821STANM+ furnace: R97MV0855A21DHCold climate designationAHRI reference: 216820084 | 17.00 | 10.00 | 37800 | 2.10 | EPA 4028252 → |
RCFY4824STANM+ furnace: R921V0855A21M4Cold climate designationAHRI reference: 216820109 | 17.00 | 10.00 | 37800 | 2.10 | EPA 4028255 → |
RCFY4824STANM+ furnace: R951V0705A21UHUCold climate designationAHRI reference: 216820115 | 17.00 | 10.00 | 37800 | 2.10 | EPA 4028257 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →