Rheem / AIR-SOURCE HEAT PUMP

RD18AY48AJVC

PRESTIGE SERIES · source records, page 5

112 published source records · source checked Sep 21, 2026

SEER2 range16–19BTU/Wh
HSPF2 range8.1–10BTU/Wh
Cooling capacity40,500–43,500BTU/h

Each efficiency range summarizes published EPA records for RD18AY48AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 112 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–19112 / 112
EER2 · BTU/Wh10–12112 / 112
HSPF2 · BTU/Wh8.1–10112 / 112
Cooling capacity · BTU/h40,500–43,500112 / 112
Heating capacity at 47°F / 8.3°C · BTU/h40,500–43,000112 / 112
Heating capacity at 17°F / −8.3°C · BTU/h35,600–40,500112 / 112
Heating capacity at 5°F / −15°C · BTU/h30,800–38,000112 / 112
COP at 5°F / −15°C2–2.2112 / 112
Equipment / loop typeHP - Split System112 / 112
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)112 / 112
Compressor stagingContinuously variable112 / 112
Connected capabilityYes112 / 112

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
RCFY4821STANM+ furnace: R962V1005A21M4Cold climate designationAHRI reference: 21681988717.0010.00378002.10EPA 4028066 →
RCFY4821STANM+ furnace: R921V0705A21M4Cold climate designationAHRI reference: 21681992117.0010.00378002.10EPA 4028072 →
RCFY4821STANM+ furnace: R98MV0855A21UPCold climate designationAHRI reference: 21681992617.0010.00378002.10EPA 4028074 →
RCFY4821STANM+ furnace: R962V0855A21M4Cold climate designationAHRI reference: 21681993117.0010.00378002.10EPA 4028076 →
RCFY4824STANM+ furnace: R962V1005A21M4Cold climate designationAHRI reference: 21681995517.0010.00378002.10EPA 4028081 →
RCFY4824STANM+ furnace: R921V0705A21M4Cold climate designationAHRI reference: 21681997117.0010.00378002.10EPA 4028086 →
RCFY4821STANM+ furnace: R802V1004A17UHCold climate designationAHRI reference: 21682014717.008.10378002.10EPA 4028124 →
RCFY4821STANM+ furnace: R921V0855A21M4Cold climate designationAHRI reference: 21682000317.0010.00378002.10EPA 4028138 →
RCFY4821STANM+ furnace: R951V0855A21M4Cold climate designationAHRI reference: 21682001817.0010.00378002.10EPA 4028141 →
RCFY4821STANM+ furnace: R951V1005A21M4Cold climate designationAHRI reference: 21682002417.0010.00378002.10EPA 4028143 →
RCFY4824STANM+ furnace: R951V1005A21M4Cold climate designationAHRI reference: 21682004117.0010.00378002.10EPA 4028149 →
RCFY4824MTANM+ furnace: R962V0705A21M4Cold climate designationAHRI reference: 21681949017.009.50334002.00EPA 4028151 →
RCFY4824MTANM+ furnace: R97MV1155A24DHCold climate designationAHRI reference: 21681949917.009.50334002.00EPA 4028153 →
RCFY4824MTANM+ furnace: R97MV0855A21DHCold climate designationAHRI reference: 21681952417.009.50334002.00EPA 4028159 →
RCFY4824MTANM+ furnace: R921V0855A21M4Cold climate designationAHRI reference: 21681952917.009.50336002.00EPA 4028161 →
RCFY4824MTANM+ furnace: R951V0705A21M4Cold climate designationAHRI reference: 21681953617.009.50334002.00EPA 4028163 →
RCFY4824STANM+ furnace: R97MV0855A21DHCold climate designationAHRI reference: 21682006517.0010.00378002.10EPA 4028250 →
RCFY4821STANM+ furnace: R97MV0855A21DHCold climate designationAHRI reference: 21682008417.0010.00378002.10EPA 4028252 →
RCFY4824STANM+ furnace: R921V0855A21M4Cold climate designationAHRI reference: 21682010917.0010.00378002.10EPA 4028255 →
RCFY4824STANM+ furnace: R951V0705A21UHUCold climate designationAHRI reference: 21682011517.0010.00378002.10EPA 4028257 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →